WTC environmental plan, EPA review, 2005

Machine-extracted title · confidence 46%

EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.

NYC-WTC_000437748–000437815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

While a standard method using a HEPA vacuum collector was used by EPA to collect most bulk dust samples (Appendix C), some bulk dust samples were collected from residential and commercial vacuum cleaner bags. Whether collected by HEPA vac or by acquiring vacuum cleaner bag, all samples are handled (sieved, split and stored) as described in the sampling QAPP in Appendix C. Many of the above samples were analyzed for slag wool content by the EPA’s National Exposure Research Eaboratory (NERE) Scanning Electron Microscopy (SEM) Eaboratory. This analysis was performed as part of the EPA’s development of a standard protocol for sample preparation and analysis (Appendix B), to determine the sample status (background or impacted) and content.

There appears to be a clear distinction between samples taken in impacted areas versus background samples. All of the impacted samples had slag wool at concentrations of greater than 100,000 fibers per gram of dust, with a range of 113,000 to 13,400,000, while all of the background samples had concentrations less than 100,000 ppm, ranging from no slag wool identified inlO samples to 92,800 fibers of slag wool per gram of dust. Based on this preliminary work, the USGS, the EPA’s Office of Research and Development, the EPA’s National Enforcement Investigations Center (NEIC), and a number of experts from the commercial testing laboratory community, worked together to develop an analytical method to identify the presence and concentration of the screening constituents (slag wool, gypsum and elements of concrete) in indoor dust. This method was reviewed by the WTC Expert Technical Panel’s signature subcommittee and is presented in Appendix B. The composition of this technical panel can be found at http://www.epa.gov/wtc/panel.

A.5.3 Screening Method Study

The hypothesis that is the foundation for the WTC dust screening method is as follows: If a unit has been impacted, those materials that arc found in WTC dust (markers) will be found in the dust collected from the unit. The materials under consideration are: 1) slag wool, 2) elements consistent with concrete, and 3) gypsum. Since slag wool is a major component of WTC collapse dust, if a sample does not contain ‘significant’ levels of this marker, the unit would not be considered to contain WTC residuals. The other markers will be used to distinguish samples containing non-WTC slag wool from those containing WTC slag wool. It is expected that data from this study will define the term ‘significant level’.

Five independent laboratories and three government laboratories will participate in this final method validation phase. One government laboratory will analyze only a small portion of the samples, but this lab was critical in the method development. Each laboratory attended a two day session during which the method was further developed and discussed, and procedures to adapt the method to suit each laboratory’s equipment were determined. Following this session, the laboratories received dust samples consisting of both confirmed background samples (10 samples plus duplicates) and a confirmed non-impacted dust spiked with varying amounts of confirmed WTC dust (6 spiked samples plus duplicates). The spiked dust contains known quantities (concentrations) of the screening materials. The labs were provided the samples “blind”, thus, they did not know which samples were pure background dust, and which were the spiked dust.

While the goal was to validate a method of differentiating between samples of dust that contain residues from the WTC collapse from those that do not, since the three primary materials (slag 11

CITY_21MC100_0 03219500

NYC-WTC_000437758

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437758Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →