STANDARD OPERATING PROCEDURES SOP: 2040 PAGE: 54 of 10 REV: 0.0 DATE: 05/17/02 COLLECTION OF INDOOR DUST SAMPLES FROM CARPETED SURFACES FOR CHEMICAL ANALYSIS USING A NILFISK GS-80 VACUUM CLEANER

1.0 SCOPE AND APPLICATION

The purpose of this Standard Operating Procedure (SOP) is to define the procedures for the collection of carpet-embedded dust samples that can be analyzed for lead, pesticides, or any other chemicals or elements. This procedure is applicable for the collection of samples on a variety of carpeted surfaces. This SOP may be modified to include the collection of dust adhering to floor surfaces but is not intended for the collection of dust containing asbestos libers.

These are standard (i.e., typically applicable) operating procedures which may be varied or changed as required, dependent upon site conditions, equipment limitations or limitations imposed by the procedure. In all instances, the ultimate procedures employed should be documented and associated with the final report.

Mention of trade names or commercial products does not constitute United States Environmental Protection Agency (U.S. EPA) endorsement or recommendation for use.

2.0METHOD SUMMARY

Sample collection is performed utilizing the Nilfisk GS-80 vacuum cleaner equipped with a high efficiency particulate air (HEPA) filter. A diagram of the Nilfisk GS-80 dust sampling apparatus is presented in Figure 1, Appendix A. Soil and other particulate matter with aerodynamic diameters of approximately 5 microns (^tm) and larger that are embedded within the carpet are collected, sieved and submitted to the laboratory' for analysis. 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE

Following collection of a sample into a dedicated collection bag, the bag is removed from the vacuum cleaner and placed into a 32-ounce(oz) glass jar or a zip-lock plastic bag. Storage of the samples at ambient temperature is appropriate for samples that will be analyzed only for metals. Samples for organic analysis should be maintained at approximately 4 + 2 degrees Celsius (*t ).

4.0INTERFERENCES AND POTENTIAL PROBLEMS

There are no known interferences with this method.

5 .OEQUIPMENT/APPARATUS

5.1 S ampling E quipment

Nilfisk Model GS-80 vacuum cleaner Two-meter folding rider or similar device Masking tape

54

CITY_21MC100_0 03219543

NYC-WTC_000437801

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437801Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →