-Surgical gloves. Thomas Scientific Catalog No. 5761-W14.

-Disposable dust mask. Thomas Scientific Catalog No. 8055- M20.

-Camel=s Hair Brush. Fisher Scientific Catalog No. 03-655.

-Clean aluminum foil.

-Kimwipes J or other laboratory tissue.

2. Wearing clean surgical gloves to handle the bags and a dust mask for dust protection, retrieve the vacuum collection bags from the 32-ounce glass jars used to transport the bags from the field to the laboratory.

3. Empty the contents of the bag into the No. 100-mesh sieve screen through the bag opening. Complete this operation by removing the plastic adaptor from the collection bag inlet. Shake the bag as necessary to ensure all the contents have been transferred through the screen to the receiver pan.

4. Place the cover on the sieve screen and manually or mechanically shake the sieve for a minimum of 5 minutes and a maximum of 10 minutes until all the fine dust particles are collected in the bottom receiver pan. If manual shaking is performed, the directions in D- 422 of ASTM must be followed; ^Conduct the sieving operation by means of a lateral and vertical motion of the sieve, accompanied by a jarring action in order to keep the sample moving continuously over the surface of the sieve. Continue sieving until not more than 1 mass percent of the residue on a sieve passes that sieve during 7 minute of sieving®.

If mechanical shaking is performed, set up the recommended sieve shaker on an even and stable surface. Proceed with the sieving operation following directions in the manufacturer=s manual.

5. Re-weigh the receiving pan utilizing the analytical balance. The difference in weight is the weight of the sieved sample. If total weight of material is desired, the coarse material remaining on top of the sieve must be collected on a pre-weighed sheet of aluminum foil, re-weighed and the weight added to the weight of the sieved sample.

6. Transfer the sieved sample from the receiving pan to an 8-ounce wide mouth glass jar. Use the camcUs hair brush to ensure complete transfer of the sample. Cap glass jar and secure sample.

7. Document each sample. Each sample must be provided with the following information: identification number, date of sampling, location, analysis requested. Each sample must be recorded into a chain-of-custody form before delivery to the analytical laboratory.

8. Before processing the next sample, thoroughly wipe clean the shaker sieve set with a Kimwipe . Wait until dry. Repeat steps 1 through 7.

7.5 Sampling Train Decontamination

4

CITY_21MC100_004068072

NYC-WTC_000321813

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321813Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →