Document / 7 pages

Collection of [name] Samples, Nilfisk method

Machine-extracted title · confidence 34%

Procedural table for collecting samples using Nilfisk equipment.

NYC-WTC_000321809–000321815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

collected with a dedicated sampling train that has been properly assembled, cleaned, and decontaminated to ensure sample integrity. The size/weight of each sample is dependent on the goals and objectives of the sampling event, the analyses requested, and the desired method detection levels (MDLs). A 100-gram sample is highly desirable if multiple analyses (metals, pesticides, etc.) are requested. A minimum 5-10-gram sample is required for metal analysis.

3. Utilizing the 2-meter folding ruler or any other measuring device, outline and mark the recommended l-m^ portion of the carpet to be sampled.

4. Begin the sample collection at one corner of the delineated sample area, moving the sampler back and forth four times over a strip running in a straight line between the defined sampling area edges. The width of the strip is defined by the width of the sampling nozzle. After completing the first strip, angle over to the second strip gradually on the next pass, again completing four double passes.

5. Continue sampling the area delineated until an adequate sample is collected. To determine if adequate sample weight will be collected, one must use visual judgement or perform the finger judgement test on the carpet to judge the dust loading of the carpet and make a decision on whether to sample the recommended l-m^ area or a larger area. If sampling a larger area, measure the area accurately and document.

6. Wearing surgical gloves, make sure to tap with your hand on the nozzle inlet to dislodge any dust remaining in the nozzle or the hose. This procedure will ensure complete sample recovery. Turn off the vacuum cleaner and allow to sit undisturbed for at least 30 seconds. Unsnap the two vacuum container clips to access the inside of the container. Remove the polyliner and the vacuum collection bag within it. Then seal off the polyliner with the vacuum collection bag inside, and transfer to a properly labeled 32-oz. glass jar. Document the sample and store for shipping to the laboratory.

7.4 Laboratory Operations

Upon arrival at the laboratory, recovery of the dust samples from the GS-80 dedicated collection bags is accomplished by the following procedure:

1. Select a clean working area in the laboratory where recovery of the samples is to be performed (a 4-foot by 4-foot area will be sufficient). Make sure that the following equipment/apparatus is available, assembled, and in good working condition:

-Shaker sieve (No. 100), as specified in ASTM D-422 with particle size separation of 150 micrometers (Om). A complete set consists of three components: the cover, the screen, and the receiver pan. The receiver pan must be pre-weighed and its weight recorded.

-Sieve shaker for mechanical sieving. Models readily available are CSC Scientific Company, Inc. Catalog No. 18480 and Thomas Scientific Catalog No. 8324-AlO (Tel 800 345-2100).

-Analytical balance sensitive to a minimum 0.1 milligrams (mg) and weighing range of 0.1 mg to 1000 grams (g).

3

CITY_21MC100_004068071

NYC-WTC_000321812

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321812Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →