equipment into a 55-gallon drum and store in a secure area (fenced, if possible).

6.10 Groundwater (Probe)

1. Be certain sample location is noted on Location Sketch (see Section 8.1).

2. Remove the laboratory precleaned sample containers from sample cooler, label container with an indelible marker, fill out Sample Information Record and Chain of Custody Form.

3. Obtain a sample by using a dedicated polyethylene tubing equipped with a bottom check valve.

4. Gently pour the sample into the sample container taking care not to spill on the outside of the container or overfill container and replace cover on the sample container. Samples for volatile organic analyses will have no air space in the sample vial prior to sealing. This is done by filling the vial such that there is a meniscus on top. Carefully slide the septum. Teflon side down, onto the top of the vial and cap the vial. Check for bubbles by turning the vial upside down and tapping it lightly. If bubbles appear, reopen the vial, remove the septum and add more sample (or resample). Replace the septum, recap and check for bubbles. Continue until vial is bubble-free.

5. After sample collection, obtain field measurements including pH, conductivity, temperature and turbidity.

6. If a sample is to be collected for metals analysis, the turbidity must be less than 50 NTUs. If the turbidity cannot be reduced to less than 50 NTUs, the sample will be filtered in the field or by the laboratory. Both filtered (soluble metals) and unfiltered (total metals) samples will be analyzed.

7. Return sample containers to sample cooler.

8. Place all disposable personal protective equipment and disposal sampling equipment into a 55-gallon drum and store in a secure area (fenced, if possible).

6.11 Groundwater (Hydropunch)

1. Be certain sample location is noted on Location Sketch (see Section 8.1).

2. Using hydropunch equipment drive/punch screen to desired depth.

3. Remove inner sleeve and lower down decontaminated hydropunch bailer.

eD1519\A0930701.doc 6-12

CITY_21MC100_009947937

NYC-WTC_000455832

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455832Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →