Air monitoring contract requirements, DEP

Machine-extracted title · confidence 46%

Contract requirements for air monitoring/analysis with regulatory compliance references.

NYC-WTC_000454914–000454916
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

A minimum of 3 samples for small asbestos projects and a minimum of 5 samples for large projects shall be collected and analyzed. At a minimum, 1-area sample on small projects and 2- area samples on large projects shall be taken inside the work area during clean-up activities. One area sample shall be taken at the interior of the building within 10 feet of each access to the roof. Sampling must be conducted during the entire work shift. The sample volumes required would range from 1200 to 1800 liters at flow rates between 2 to 10 liters/min. Extreme care must be given to avoid overload on the filter surface.

Air sampling equipment shall not be placed in corners or near obstructions. Eocations near vents and other structures on the roof which would unduly affect airflow shall be avoided.

The work area shall be allowed to dry completely before the visual inspection is conducted. The visual inspection shall confirm the absence of visible debris in the work area, including but not limited to the roof surface, the gutters, the drains, parapets, etc. A technician must be available in the vicinity when the area is dry to perform the visual inspection. Air sampling shall be considered satisfactory when each sample is found to be below 70 s/mm’ by TEM analysis. Post abatement clearance air sampling shall not be required provided that all samples collected during the clean-up activities are below 70 s/mnr

Project 2 Start Date: April 5,2002

Air Monitoring will be required daily at 20 street level sites in the vicinity of the World Trade Center. The sites are listed below but the locations may change periodically. One sample must be collected at each site with sample duration of 45 minutes and a flow rate of 15 liters per minute . Sampling and analysis must be conducted in accordance with the NIOSH 7400 Method. Sampling must be done during regular business hours starting after 0800 hours each day. Each site must be manned at all times during sampling, therefore a minimum of 3 APST is required for this project.

Samples results above O.Olf/cc must be analyzed by TEM . Sampling Sites: Site # Location 4 River Terrace & Chambers Street 6A River Terrace Park Area between Park Place & Warren Street 7 Warren Street & North End Avenue 8 West Street & Warren Street 9 River Terrace & Park Place West. 10 North End Avenue & Park Place West 11 Murray Street & Greenwich Street 12 Murray Street & Church Street 15 Park Place & Greenwich Street 16 Park Place & Church Street 17 River Terrace & Vesey Street 20A Vesey Street & West Broadway 21 Fulton Street & Church Street 27 Gateway Plaza Park Area 29 Trinity Place & Thames Street 31 South End Ave & Albany Street 32 West Street & Albany Street 33A Rector Place by the Park Place

CITY_21MC100_008756194

NYC-WTC_000454915

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454915Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000362773

Contract scope of work for asbestos air monitoring and analysis services with NYC DEP.

Similar indexed content

NYC-WTC_000141438 · Box DEP Box 05

Contract scope defining regulatory compliance and bidding requirements for air monitoring services at the World Trade Center site.

Similar indexed content

Compare copies and versions →