with generally accepted industrial hygiene practices. Three samples were submitted
for PCBs. A lab blank was provided by PSC. Each sample was analyzed for seven
PCBs with different chlorine contents. Samples were collected from locations
specified by the parents association consultant. The PCB results were below the
limits of detection (0.5 micrograms/sample) for all three samples. One sample for
hydrogen cyanide was collected in the hallway by the cafeteria. PSC provided a lab
blank. No cyanide was detected above the level found in the blank. In a letter dated
January 10, 2002, ATC reported the results from December 15, 2001 air sampling for
dioxins at P.S. 89M. Four samples were collected for twenty-four hours using
polyurethane foam (PUF) cartridges and General Metal Works samplers. Total
sample volumes were 425 to 446 cubic meters of air (m^). Pumps were calibrated
using vendor-provided software and a laptop computer. Two samples were collected
inside the building and two were collected outdoors. The PUFs were provided and
analyzed by Pace Analytical Services, Inc. The analysis was performed by Method
TO-9 with modifications from EPA Method 23 using combined capillary column gas
chromatography/high resolution mass spectrometry. The sampling locations were
specified by the parents association consultant. Each sample was analyzed for
seventeen PCDD/PCDF isomers. The results for each isomer were then converted to
2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying
by an established equivalency factor in order to obtain a single value for the
analytical results for each sample. The indoor dioxin concentrations were 0.0013 and
0.0023 pg/m\ The outdoor concentrations were 0.00039 and 0.00043 pg/nT. All
concentrations were below the EPA screening level of 0.16 ng/m\
11. In a letter dated January 3, 2002, ATC reported the results from December 20, 2001
wipe samples for metals taken at P.S. 89M. Metals were detected in all ten samples,
however only one sample, contained measurable levels of the nine metals detected.
No single sample contained the highest measured metal concentrations. Aluminum,
chromium, copper, iron, magnesium and manganese were found in all samples.
Molybdenum was not found in any sample above the reporting limit. Magnesium and
zine were also recovered from the blank. Detectable levels of ten metals were found
in the samples from ten interior surfaces. However, ATC does not believe that
cleaning of the surfaces in the school is necessary. In a letter dated Januaiy 18, 2002,
ATC reported the results for January 11, 2002 wipe samples for metals taken at P.S.
89M. Metals were detected in all three samples however; Cd, Co, Mo and Ni were
not detected. Al, Cu, Fe, Mg and Zn were found in all samples. Chromium was
detected in one sample. All of the metals detected, except Cr, were also found in the
blank. Cu was not detected in the samples at a level greater than in the blank. Cr and
Mn were the only metals found in the samples but not in the blank. After the blank
concentration is subtracted, the Cu level drops below the detection limit. Fe and Mg
were the metals found in the highest concentration. All samples were collected using
Palintest dust wipes and were analyzed by NIOSH Method 7300M. In a letter dated
January 4, 2002, ATC reported the results from wipe samples for polychlorinated
biphenyls (PCBs) and polynuclear aromatic hydrocarbons (PAHs) collected on
December 20, 2001 at P.S. 89M. The samples were collected using sterile gauze pads
and hexane as a solvent and were analyzed using EPA Method 8082B. The PAHs