Lead-in-dust wipe sampling at PS 89M, Jan 2002

Machine-extracted title · confidence 45%

TEM analysis of lead-in-dust wipes inside PS 89M and outdoor playground, Jan 2002.

NYC-WTC_000454704–000454711
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pumps were calibrated before and after each sampling period. Analysis was performed by gas chromatography/mass spectrometry according to EPA Method TO- l/TO-2 (TO-17). Each sample was analyzed for a panel of twenty-three specific TOCs. The sampling locations were specified by the parents association consultant. On December 15, 2001, two samples were collected inside the building and two were collected outside. Eive of the TOCs in the panel were detected in the samples. Unknown peaks were also found in each sample. The EPA has set screening level for benzene of 20ppb based on continuous exposure for one year. The benzene levels detected ranged from Not Detected to 1.9 ppb. On January 11, 2002, two samples were collected inside the building and one was collected outside. Eive of the TOCs in the panel were detected in the samples. Unknown peaks were also found in each sample.

9. In a letter dated January 9, 2002, ATC reported the results from air sampling for polynuclear aromatic hydrocarbons conducted on December 15, 2001 at P.S. 89M. The samples were collected using Teflon filters and XAD-2 tubes connected in series to battery-powered saiupling pumps set at a flow rate of 2.0 liters per minute. Analysis was performed according to NIOSH Method 5506. The sampling was performed consistent with generally accepted industrial hygiene practices. ATC submitted three samples to PSC for analysis PSC provided a lab bank. The minimum collection time for each sample was ten hours. Samples were collected from locations specified by the parents association consultant. Each sample was analyzed for sixteen PAHs. PAHs were detected in one outdoor sample and one indoor sample. OSHA has a Permissible Exposure Eimit (PEL) for PAHs of 0.2 mg/m\ This is approximately three orders of magnitude greater than the levels found in these samples, however the PEL is intended for industrial exposures.

10. **In a letter dated January 9, 2002, ATC reported the results of air sampling for metals at P.S. 89M. Four samples were collected for a minimum of ten hours using 37 mm mixed cellulose ester filters connected to battery-powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling period. Two samples were collected from inside the building and two were collected from outside. One blank sample was also submitted. Analysis was performed by NIOSH Methods 7300M. Each sample was analyzed for a panel of eleven metals. The sampling locations were specified by the parents association consultant. The established regulatory values for metals are intended for industrial exposures. The only metal that was found above the limit of detection was copper, which was found in both indoor samples and one outdoor sample. The EPA has no published screening level or guidelines for copper in ambient air. In a letter dated January 9, 2002, ATC reported the results of air sampling for polychlorinated biphenyls & cyanide conducted on December 15 at P.S. 89M. The PCB samples were collected using glass fiber filters and Florisil tubes connected to in series to battery-powered sampling pumps set at a flow rate of 0.2 liters per minute (1pm). The sampling time was ten hours. The cyanide sample was collected using a soda lime tube and a battery-powered pump at a flow rate of 0.2 1pm. Analysis was performed by PSC according to NIOSH Method 6010. The sampling was performed consistent

3

CITY_21MC100_0 12559411

NYC-WTC_000454706

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454706Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000234707

Correspondence summarizing safety reports for IS 89M based on asbestos and lead testing conducted in late 2001.

Similar indexed content

Compare copies and versions →