Pumps were calibrated before and after each sampling period. Analysis was
performed by gas chromatography/mass spectrometry according to EPA Method TO-
l/TO-2 (TO-17). Each sample was analyzed for a panel of twenty-three specific
TOCs. The sampling locations were specified by the parents association consultant.
On December 15, 2001, two samples were collected inside the building and two were
collected outside. Eive of the TOCs in the panel were detected in the samples.
Unknown peaks were also found in each sample. The EPA has set screening level for
benzene of 20ppb based on continuous exposure for one year. The benzene levels
detected ranged from Not Detected to 1.9 ppb. On January 11, 2002, two samples
were collected inside the building and one was collected outside. Eive of the TOCs in
the panel were detected in the samples. Unknown peaks were also found in each
sample.
9. In a letter dated January 9, 2002, ATC reported the results from air sampling for
polynuclear aromatic hydrocarbons conducted on December 15, 2001 at P.S. 89M.
The samples were collected using Teflon filters and XAD-2 tubes connected in series
to battery-powered saiupling pumps set at a flow rate of 2.0 liters per minute.
Analysis was performed according to NIOSH Method 5506. The sampling was
performed consistent with generally accepted industrial hygiene practices. ATC
submitted three samples to PSC for analysis PSC provided a lab bank. The minimum
collection time for each sample was ten hours. Samples were collected from
locations specified by the parents association consultant. Each sample was analyzed
for sixteen PAHs. PAHs were detected in one outdoor sample and one indoor
sample. OSHA has a Permissible Exposure Eimit (PEL) for PAHs of 0.2 mg/m\
This is approximately three orders of magnitude greater than the levels found in these
samples, however the PEL is intended for industrial exposures.
10. **In a letter dated January 9, 2002, ATC reported the results of air sampling for
metals at P.S. 89M. Four samples were collected for a minimum of ten hours using
37 mm mixed cellulose ester filters connected to battery-powered sampling pumps at
a flow rate of 2 liters per minute. Pumps were calibrated before and after each
sampling period. Two samples were collected from inside the building and two were
collected from outside. One blank sample was also submitted. Analysis was
performed by NIOSH Methods 7300M. Each sample was analyzed for a panel of
eleven metals. The sampling locations were specified by the parents association
consultant. The established regulatory values for metals are intended for industrial
exposures. The only metal that was found above the limit of detection was copper,
which was found in both indoor samples and one outdoor sample. The EPA has no
published screening level or guidelines for copper in ambient air. In a letter dated
January 9, 2002, ATC reported the results of air sampling for polychlorinated
biphenyls & cyanide conducted on December 15 at P.S. 89M. The PCB samples
were collected using glass fiber filters and Florisil tubes connected to in series to
battery-powered sampling pumps set at a flow rate of 0.2 liters per minute (1pm). The
sampling time was ten hours. The cyanide sample was collected using a soda lime
tube and a battery-powered pump at a flow rate of 0.2 1pm. Analysis was performed
by PSC according to NIOSH Method 6010. The sampling was performed consistent
3