assessment at P.S. 89M. The findings and conclusions are based on visual
observations, the real-time environmental measurements and conditions present in the
school at the time of the assessment. ATC recorded concentrations of respirable
particulates (PM2.5) for 24 hours with a Dust-Trak Aerosol Monitor Model 8520.
Samples of PM2.5 for gravimetric analysis were also collected for 24 hours using a
Micro Environmental Monitor (MEM). The gravimetric samples were collected on
pre-weighed PVC filters. The assessment was performed with generally accepted
indoor air quality assessment practices. Sample results for both dates were below the
EPA NPAAQS for PM25 of 65 ug/m’ (24-hour average) and the recommended level
of 40 ug/m\
6. **In a letter dated December 19, 2001, ATC reported the results from the real-time
air monitoring conducted on December 15-16, 2001 at P.S. 89M. Basic indoor air
quality (lAQ) parameters of temperature, relative humidity, carbon dioxide (CO2) and
carbon monoxide (CO) were measured with a Q-Trak Model 8551. In addition, total
volatile organic compounds (TVOCs) were measured using a MiniRAE
photoionization detector. Sulfur dioxide (SO2), hydrogen sulfide (H2S), nitric oxide
(NO) and nitrogen dioxide (NO2) were also measured. Respirable particulates (PM2.5)
were monitored for 24 hours in three locations using a Dust Trak Aerosol Monitor
Model 8520. The assessments were performed according to generally accepted
indoor air quality assessment practices. Currently, there are no regulatory standards
for indoor air quality in non-industrial buildings. For the real-time data collected,
ATC used commonly accepted guidelines from trade associations. Measurements of
concentrations of CO, TVOCs and respirable particulates were below recommended
maximums. Temperature and relative humidity measurements and CO2
concentrations were below the ASHRAE-recommended ranges, however the building
was unoccupied. H2S, NO and SO2 were not detected. NO2 was detected at similar
levels indoors and outdoors.
7. In a letter dated December 21, 2001, ATC reported the results from air sampling for
mercury conducted on December 15 at P.S. 89M. Pour samples for mercury vapor
were collected using Carulite (Hydrar) tubes connected to battery-powered sampling
pumps calibrated to collect 0.2 liters of air per minute. Two samples were collected
indoors and two were collected outdoors. One blank tube along with the samples was
submitted to PSC Analytical Services for analysis. Analysis was performed by
means of a mercury analyzer according to NIOSH Method 6009. Mercury was not
detected in levels greater than that detected in the blank sample.
8. In a letter dated December 27, 2001, ATC reported the results from air sampling for
toxic organic compounds on December 15, 2001 at P.S.89M. ATC collected four
samples for toxic organic compounds (TOC) at specified locations. In a letter dated
January 21, 2002, ATC reported the results from air sampling for toxic organic
compounds on January 11, 2002 at P.S.89M. ATC collected three air samples for
toxic organic compounds (TOC) at specified locations. On both dates, samples were
collected for a minimum of one hundred minutes using Supelco sampling tubes
connected to battery-powered sampling pumps at a flow rate of 0.15 liters per minute.