NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

Lead-in-dust wipe sampling at PS 89M, Jan 2002

Machine-extracted title · confidence 45%

TEM analysis of lead-in-dust wipes inside PS 89M and outdoor playground, Jan 2002.

NYC-WTC_000454704–000454711
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

assessment at P.S. 89M. The findings and conclusions are based on visual observations, the real-time environmental measurements and conditions present in the school at the time of the assessment. ATC recorded concentrations of respirable particulates (PM2.5) for 24 hours with a Dust-Trak Aerosol Monitor Model 8520. Samples of PM2.5 for gravimetric analysis were also collected for 24 hours using a Micro Environmental Monitor (MEM). The gravimetric samples were collected on pre-weighed PVC filters. The assessment was performed with generally accepted indoor air quality assessment practices. Sample results for both dates were below the EPA NPAAQS for PM25 of 65 ug/m’ (24-hour average) and the recommended level of 40 ug/m\

6. **In a letter dated December 19, 2001, ATC reported the results from the real-time air monitoring conducted on December 15-16, 2001 at P.S. 89M. Basic indoor air quality (lAQ) parameters of temperature, relative humidity, carbon dioxide (CO2) and carbon monoxide (CO) were measured with a Q-Trak Model 8551. In addition, total volatile organic compounds (TVOCs) were measured using a MiniRAE photoionization detector. Sulfur dioxide (SO2), hydrogen sulfide (H2S), nitric oxide (NO) and nitrogen dioxide (NO2) were also measured. Respirable particulates (PM2.5) were monitored for 24 hours in three locations using a Dust Trak Aerosol Monitor Model 8520. The assessments were performed according to generally accepted indoor air quality assessment practices. Currently, there are no regulatory standards for indoor air quality in non-industrial buildings. For the real-time data collected, ATC used commonly accepted guidelines from trade associations. Measurements of concentrations of CO, TVOCs and respirable particulates were below recommended maximums. Temperature and relative humidity measurements and CO2 concentrations were below the ASHRAE-recommended ranges, however the building was unoccupied. H2S, NO and SO2 were not detected. NO2 was detected at similar levels indoors and outdoors.

7. In a letter dated December 21, 2001, ATC reported the results from air sampling for mercury conducted on December 15 at P.S. 89M. Pour samples for mercury vapor were collected using Carulite (Hydrar) tubes connected to battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. Two samples were collected indoors and two were collected outdoors. One blank tube along with the samples was submitted to PSC Analytical Services for analysis. Analysis was performed by means of a mercury analyzer according to NIOSH Method 6009. Mercury was not detected in levels greater than that detected in the blank sample.

8. In a letter dated December 27, 2001, ATC reported the results from air sampling for toxic organic compounds on December 15, 2001 at P.S.89M. ATC collected four samples for toxic organic compounds (TOC) at specified locations. In a letter dated January 21, 2002, ATC reported the results from air sampling for toxic organic compounds on January 11, 2002 at P.S.89M. ATC collected three air samples for toxic organic compounds (TOC) at specified locations. On both dates, samples were collected for a minimum of one hundred minutes using Supelco sampling tubes connected to battery-powered sampling pumps at a flow rate of 0.15 liters per minute.

CITY_21MC100_0 12559410

NYC-WTC_000454705

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454705Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000234707

Correspondence summarizing safety reports for IS 89M based on asbestos and lead testing conducted in late 2001.

Similar indexed content

Compare copies and versions →