NYC 9/11 Public Portal Document
1. In a letter dated January II, 2002, ATC Associates deemed I.S. 89M safe for re
occupancy based on the analysis of forty-nine Transmission Electro Microscopy
(TEM) samples conducted on January 10, 2002. The analysis was conducted in strict
conformance with the methodology of the AHERA Final Rule.
2. November 6, 2001 TEM analysis report of air samples from the entire 201 Warren
Street building, which was performed in strict conformance with the methodology of
the AHERA Final Rule. Less than 70 asbestos structures per mm’ were detected in
all of the twenty-six interior ambient samples submitted from the site.
3. January 2002 limited lead-in-dust wipe sampling report for P.S. 89M, containing the
results of twenty dust wipe samples from locations inside the school and three from
the outdoor playground. These sites were indicated for testing by the Parents
Association environmental consultant, Tom Fusillo of Environ. The samples were
obtained by gently wiping a pre-measured surface area with non-alcohol moistened
towelettes. Laboratory analysis has shown that all samples collected contain lead
below the floor and windowsill surface clearance guideline levels of 40|4/fE and 250
P-g/fE respectively.
4. **In a letter dated November 12, 2001, ATC reported the results from the November
2, 2001 settled dust sampling for asbestos test for P.S. 89M. Thirty-three bulk and six
soil samples were analyzed utilizing Polar Light Microscopy (PLM). Furthermore,
twenty-nine settled dust samples, utilizing the Scotch Magic Tape were collected
from areas inside the school building where the collection of a bulk sample was not
possible. A NYC-BOE representative on site indicated the locations and materials
to be sampled. All sixty-eight dust samples were analyzed utilizing Polarized Light
Microscopy (PLM). Analytical results indicated the presence of asbestos in the
amount greater than 1% within the bulk sample collected from settled dust on soil.
All other settled dust samples were found to contain either none or less than 1%
asbestos. In a letter dated December 12, 2001, ATC reported the results from the
December 11, 2001 settled dust sampling for asbestos test for P.S. 89M. Six settled
dust bulk samples were analyzed utilizing Polar Light Microscopy (PLM). A NYC-
SCA representative on site indicated the locations and materials to be sampled.
Analytical results indicated that two collected settled dust bulk samples contained
traces of asbestos fibers. The other four samples were found to contain no asbestos
fibers. In a letter dated January 17, 2002, ATC reported the results from the January
11, 2001 settled dust sampling for asbestos test for P.S. 89M. Ten settled dust
samples were collected using the Scotch Magic Tape method. An ENVIRON
Consultant on site indicated the locations and materials to be sampled. Dust samples
were analyzed utilizing Polarized Light Microscopy (PLM). Analytical results
indicated that none of the ten collected settled dust samples contained fiberglass
fibers.
5. In a letter dated January 22, 2002, ATC reported the results from the January 11-12,
2002 respirable particulate assessment at P.S. 89M. In a letter dated January 30,
2002, ATC reported the results from the January 25-26, 2002 respirable particulate
1
CITY_21MC100_0 12559409
NYC-WTC_000454704
OCR can misread numbers and units. Confirm readings against the page image before using them.