NYC 9/11 Public Portal Document
Polychlorinated Biphenyls and Polycyclic Aromatic Hydrocarbons
None of the ten surface samples contained PCBs at concentrations above the laboratory
method reporting level (2 ug). None of the ten surface samples contained polycyclic
aromatic hydrocarbons above the laboratory method reporting limit (5 ug).
Dioxin/Dibenzofurans
Trace levels of dioxins and dibenzofurans were detected in nine of the ten surface wipe
samples collected, as expected. Only the sample collected from the gymnasium floor did
not contain any measurable dioxin. TCDD equivalent concentrations were reported at
highest concentrations in three wipe samples collected from windowsills (0.017 to 0.041
ng/m^) and lower in samples collected from tabletops and bookcases (0.00018 to 0.00074
ng/m^). There are no established standards for dioxins/dibenzofurans on surfaces. The
National Research Council (1988) has a published a recommended surface criterion for
dioxins of 25 ng/m^ for an office building setting, and cites recommended concentrations
in several states ranging from 1 to 25 ng/m*. ENVIRON developed a preliminary
screening level of 0.055 ng/n? using a USEPA risk-based approach, reasonable exposure
assumptions for a school setting, and very protective risk targets (10'®). All of the
reported TCDD equivalent concentrations were less than the preliminary screening level,
and well below the recommended criteria cited by the National Research Council.
Metals
Metals were detected in all samples, as expected. Common metals, such as iron, copper,
manganese, and zinc were detected in all 10 samples, Trace metals, such as chromium,
cadmium, and nickel, were detected in four or less of the samples. Only lead has
regulatory levels for surface dust (lead was discussed above). ENVIRON developed
preliminary screening levels for the analyzed metals utilizing a USEPA risk-based
approach, with reasonable exposure assumptions for a school setting, and very protective
risk targets (10'^). All of the detected metal concentrations were below the preliminary
screening levels.
Mold Assessment
Because there was some minor flooding in the basement of the school in the few days
immediately after September 11, an assessment was performed to determine if there were
any issues related to mold growth or fungal spores in the school. An inspection was
performed of the basement by ATC Associates on October 31 which found no evidence
of microbial growth or mold growth evident. ENVIRON performed a follow-up
inspection and made the same observations. To confirm those observations, sampling for
fungal spore counts was performed inside and outside the school on December 18, 2001.
That sampling found that spore counts inside the school were lower than outside the
school, indicating no evidence of amplified fungal growth in the school.
r
9
CITY_21MC100_006753565
NYC-WTC_000337669
OCR can misread numbers and units. Confirm readings against the page image before using them.