Instrument readings for total volatile organic compounds, nitrous oxide, sulfur
dioxide, and hydrogen sulfide were all below the instrument detection limit. Nitrogen
dioxide was measured at average concentrations ranging from 0.1 ppm to 0.3 ppm
indoors, and 0.2 ppm to 0.4 ppm outdoors. These levels exceed the USEPA ambient air
quality standard of 0.053 ppm. These readings are believed to be the result of instrument
error. Re-testing using a more sensitive meter at a nearby school confirmed instrument
error from the earlier readings at that school and re-testing of nitrogen dioxide levels at
PS 234 have confirmed this conclusion, based on information received verbally from
ATC.
Wipe Samples
Dust Sampling for Asbestos (December 5,2001)
A total of 22 dust samples were collected from throughout the school on December 5 for
analysis of asbestos. ATC reported that no asbestos was detected in any of the 22 dust
samples.
Comprehensive Surface Sampling (December 5,2001)
Ten wipe samples were collected from various locations inside PS 234 on December 6,
2001 for a variety of potential contaminants, including dioxins and dibenzofurans, metals,
polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs). The
sample locations included:
• Cafeteria - windowsill
• Kitchen - serving windowsill
• Room 116 - table surface
• Room 120 - windowsill
• Room 211 - table surface
• Library - table surface
• Library - bookcase surface
• Room 305 - bookcase surface
• Room 316 - table surface
• Gymnasium - landing.
The results of the analyses of these samples are discussed below.