consistent with either or both of those operations as the potential source of the trace
levels detected.
None of the target hydrocarbons, including volatile organic compounds such as
benzene, were not detected in any of 8 air samples collected from inside or outside the
school on December 9 or 11,2001.
Volatile Organic Compounds plus Library Search (December 1 SjlOO 1
Five air samples were collected for analysis of volatile organic compounds with a 15-
compound forward library search (VOC-rlo) on December 15, 2001. Sampling locations
included three outdoor samples (main entrance, roof, and the rear playground) and two
indoor samples (cafeteria and second floor hallway). A few targeted VOCs were detected
at trace levels both outside and inside the school, including benzene (maximum 0.9 ppb
outside, 0.8 ppb inside), ethylbenzene (0.3 ppb outside, 1.0 ppb inside), toluene (1.6 ppb
outside, 2.8 ppb inside), and xylenes (1.5 ppb outside, 4.7 ppb inside). In addition,
several non-target VOC compounds were detected both inside and outside of the school.
Overall, the type and levels of VOCs detected are generally consistent with urban
backgroxmd concentrations documented by USEPA.
Particulates and Other Air Quality Parameters (December 8 to 14,2001)
Levels of carbon dioxide, carbon monoxide, and relative humidity were within guideline
ranges. Levels of particulates (PM2.5) varied significantly during the period. Based on
periodic measurements taken at several locations inside and outside of the school, the
average particulate levels on all five days (indoor averages ranged from 22 to 36 ug/m’)
were below the threshold level of 40 ug/nv* used by USEPA for sensitive receptors inside
the school, although some instantaneous particulate measurements were higher, up to 68
ug/m^, which is slightly above the 65 ug/m^ guideline used by USEPA for normal
populations. It should be noted that the 40 ug/m^ and 65 ug/m^ limits are established for
outdoor conditions as an average concentration over 24 hours. Outdoor levels were
approximately similar to indoor readings on December 8 and 9, but outdoor readings
were higher than indoor readings on December 10 and 12, with average outdoor readings
of 51 ug/m^ on December 10 and 52 ug/n? on December 12.
In addition to the periodic particulate monitoring conducted, three locations were
monitored continuously for approximately 24 hours during this period. One indoor
location, the cafeteria, had average particulate levels of 30 ug/nr’ on December 8-9, 44
ug/m^ on December 11-12, and 58 ug/m’ on December. Outdoor levels were somewhat
higher, with average levels on the roof exceeding 65 ug/m^ during December 12-13 and
13-14, and outside the main entrance on December 12-13. These measurements were
made with the school ventilation system shut down while improved filtration systems
were installed. Further assessment of particulate levels is warranted with the upgraded
ventilation systems operating. As previously discussed, an evaluation of the testing
method being used for particulates is also underway, along with further particulate
monitoring to assess current air quality. In general, particulate levels in the area of the
school, including at a measurement station at the Borough of Manhattan Community
College, have been well below 40 ug/m^ on most days in recent weeks.