NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
48 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗Document discussing lessons learned in children's environmental health related to Ground Zero sites.
NYC-WTC_000276036–000276449OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
consistent with either or both of those operations as the potential source of the trace levels detected. None of the target hydrocarbons, including volatile organic compounds such as benzene, were not detected in any of 8 air samples collected from inside or outside the school on December 9 or 11, 2001.
Volatile Organic Compounds plus Library Search (December 15,2001)
Five air samples were collected for analysis of volatile organic compounds -with a 15- compound forward library search (VOC+15) on December 15,2001. Sampling locations included three outdoor samples (main entrance, roof, and the rear playground) and two indoor samples (cafeteria and second floor hallway). A few targeted VOCs were detected at trace levels both outside and inside the school, including benzene (maximum 0.9 ppb outside, 0.8 ppb inside), ethylbenzene (0.3 ppb outside, 1.0 ppb inside), toluene (1.6 ppb outside, 2.8 ppb inside), and xylenes (1.5 ppb outside, 4.7 ppb inside). In addition, several non-target VOC compounds were detected both inside and outside of the school. Overall, the type and levels of VOCs detected are generally consistent with urban background concentrations documented by USEPA.
Particulates and Other Air Quality Parameters (December 8 to 14,2001)
Levels of carbon dioxide, carbon monoxide, and relative humidity were within guideline ranges. Levels of particulates (PM2.5) varied significantly during the period. Based on periodic measurements taken at several locations inside and outside of the school, the average particulate levels on all five days (indoor averages ranged from 22 to 36 ug/n?) were below the threshold level of 40 ug/m^ used by USEPA for sensitive receptors inside the school, although some instantaneous particulate measurements were higher, up to 68 ug/m^, which is slightly above the 65 ug/m’ guideline used by USEPA for normal populations. It should be noted that the 40 ug/m^ and 65 ug/m^ limits are established for outdoor conditions as an average concentration over 24 hours. Outdoor levels were approximately similar to indoor readings on December 8 and 9, but outdoor readings were higher than indoor readings on December 10 and 12, with average outdoor readings of 51 ug/m^ on December 10 and 52 ug/m^ on December 12. In addition to the periodic particulate monitoring conducted, three locations were monitored continuously for approximately 24 hours during this period. One indoor location, the cafeteria, had average particulate levels of 30 ug/m^ on December 8-9, 44 ug/m^ on December 11-12, and 58 ug/m^ on December. Outdoor levels were somewhat higher, with average levels on the roof exceeding 65 ug/m^ during December 12-13 and 13-14, and outside the main entrance on December 12-13. These measurements were made with the school ventilation system shut down while improved filtration systems were installed. Further assessment of particulate levels is warranted with the upgraded ventilation systems operating. As previously discussed, an evaluation of the testing method being used for particulates is also underway, along with further particulate monitoring to assess current air quality. In general, particulate levels in the area of the school, including at a measurement station at the Borough of Manhattan Community College, have been well below 40 ug/m^ on most days in recent weeks.
7
CITY_21MC100_012173150
NYC-WTC_000276305
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
48 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
33 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
36 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106411
Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
28 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144546
Internal memo directing DEP employees to preserve all records related to the World Trade Center attacks and subsequent environmental cleanup.
16 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
39 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
27 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144741
Standard administrative notice requiring the retention of original World Trade Center records as evidence for future legal actions.
34 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153468
Page containing illegible text and a document identifier for the EPA Inspector General series.
14 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
48 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138950
Draft excerpts of EPA OIG report for NYC interactions.
20 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318088
ASB testing results from ATC and follow-up sampling around PS 234 school building.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199886
Summary of initial and follow-up asbestos testing at PS 234 school, reporting dust and air sample results regarding fiber detection.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337662
Lab report on debris, soil and dust sampling around PS 234 with asbestos findings and abatement actions.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321465
ENVIRON evaluation of environmental data around PS 234, highlighting data collection and sampling context.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321465
ENVIRON evaluation of environmental data around PS 234, highlighting data collection and sampling context.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similar indexed content
Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000144546
Internal memo directing DEP employees to preserve all records related to the World Trade Center attacks and subsequent environmental cleanup.
Similar indexed content
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
Similar indexed content