Exterior sealant/caulking abatement specs, P.S. 92M

Machine-extracted title · confidence 53%

Specifications for asbestos-containing exterior sealants and caulking materials abatement.

NYC-WTC_000454574–000454656
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SECTION 02082 Documents.

6. The Contractor shall be responsible for and shall include in its Bid any and all fees or changes imposed by Local, State or Federal Law, Rule or Regulation applicable to the work specified herein, including fees or charges which may be imposed subsequent to the date of the Bid opening.

7. Removal of ACSM shall be in accordance with large project full containment procedures as described in NYC DEP Title 15, Chapter 1, Subchapter F and Section 4.01 of these Specifications.

8. A variance for utilizing tent procedures, as described in Section §1-106 of Title 15, Chapter 1 and Section 4.02 of these Specifications, within the Work Areas shall be applied for and approved by NYCDEP prior to the start of abatement activities. The following variances to Title 15, Chapter 1 shall be included within the variance request:

a. In lieu of hardwood barriers, the Work Area shall be enclosed with construction tarpaulin which will enclose the exterior of the entire scaffolding system; b. At street level Work Areas, a hardwood vision barrier shall be constructed. This vision barrier shall be installed to separate the Work Area(s) from the general public and shall be positioned to enclose and secure the Work Area(s) and area between the Work Area(s) and decontamination unit. These barriers shall be constructed of 4 foot by 8 foot plywood sheeting of minimum thickness of 3/8 inch. The plywood sheeting shall be fastened and supported by 2 inch by 4 inch wood or metal framing, 16 inch on center; c. Tent containments shall be utilized for all Work Areas, including those in which more than 160 square feet of material is being removed; d. Two layers of 6-mil polyethylene sheeting shall be used for tent construction; e. During abatement air samples shall be collected and shall be analyzed as final clearance air samples. The results of these analyses will be used as clearance results for reoccupancy; f. The pre and post-abatement waiting/settling periods shall be waived and breakdown shall commence once final clearance air monitoring (during samples) results are determined to be satisfactory; and g- The air filtration devices (AFDs) shall be exhausted locally and the requirement of exhausting at least 40 feet from all openings, intakes, etc. shall be waived. All openings, intakes, etc. within twenty-five feet of the Work Area will be sealed with two layers of polyethylene sheeting. h. Air monitoring procedures shall be altered as follows: (1) During abatement air samples shall be analyzed as final clearance air samples. (2) During abatement air samples shall be collected in the following locations: (a) One side-by-side PCM and TEM air sample shall be collected in each classroom which is adjacent to a Work Area; (b) One PCM air sample shall be collected in each corridor which

02082-4

CITY_21 MCI 00_014563777

NYC-WTC_000454577

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454577Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →