Bulk Asbestos Test Report Taylor environmental grour inc. Test Method: EPA 600/R-93/116 ELAP #10928 Client: NYC School Construction Authority Date Received: 12/21/01 30-30 Thomson Avenue_________ Date Analyzed: 12/21/01 Long Island City, N.Y. 11101 Analyst: Re: 90 Trinity Place LLW#: Report Ref: M894-14630

Laboratory Number 35484 35485 35486 35487 35488 35489 Sample Reference 01 02 03 04 05 06 Gross Sample Color Off White Off White Off White Gray Gray Gray Appearance Homogeneous Yes Yes Yes Yes Yes Yes w G Fibrous Yes Yes Yes Yes Yes Yes ro Asbestos Found No No No No No No M O H Type(s) & Chrysotile H Percentage(s) of Amosite O Asbestos Found Crocidolite G Other o H (Actinolite, Tremolite, Anthophyllite) M O o Total Asbestos Found ND ND H o ND ND ND ND s < G Other Fiberglass 10 70 M a Fibrous Cellulose 80 40 80 30 10 85 O M 3 Materials a H Synthetic M ?d > Non-Fibrous Carbonates G S Materials Silicates o Binder 20 60 20 60 20 15 to Location: 14 Floor Plenum 13 Floor Plenum 12 Floor Plenum 11 Floor Plenum 10 Floor Plenum 9 Floor Plenum w Dust/Debris Dust/Debris Dust/Debris Dust/Debris Dust/Debris Dust/Debris M G Room 1403 Room 1306 Room 1205 Room 1105 Room 1005 Room 906 H INC = Inconclusive to o ND = None Detected o co o NG = None Given_________________________________________________________________________________________________________________ H ** Residual weight of sample is <1.0% of original subsample weight; no further analysis is necessary. * Polarized light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before to this material can be considered or treated as non-asbestos-containing, confirmation must be made by quantitative transmission electron microscopy. (—1

s O 1) The results represented in this test report relate only to the samples tested. o 2) This test report shall not be reproduced except in full, without the written approval of Taylor Environmental Group, Inc. o I o o This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. Page 1 of 4 co wo 1 BOA JERICHO TPKE., FLORAL PARK, NY 1 1001 ■ PHONE (516) 358-2955 ■ FAX (516) 358-1780 cn Cn wo wo

NYC-WTC_000453437

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453437Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →