Bulk testing report, NYC School Construction

Machine-extracted title · confidence 38%

Bulk test report for environmental samples submitted by the NYC School Construction program.

NYC-WTC_000418777–000418779
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z Bulk^^estos Test Report Taylor envirc^iental grour fnc. Test Method: EPA6 -93/116 - z o io Client: NYC School Construction Authority Date Received: 12/21/01 Fl AP ly I Q97R • “ m „

I O $2 -i I 30-30 Thomson Avenue Date Analyzed: 12/21/01 ■g -D o I c o ru CT o Long bland City, N.Y. 11101 Analyst: G) G) o' Re: OOTnnityPlace LLW#: Report Ref: HS of Economics 00 "0 o G) 3. 00 Laboratory Number 35490 35491 35492 35493 35494 35495 ID 92. O Sample Reference 07 08 09 10 11 12 o o c Gross Sample Color Gray Off White Gray Off White Off White Off White 3 CD Appearance Homogeneous Yes Yes Yes Yes Yes Yes O

Fibrous Yes Yes Yes Yes Yes Yes Asbestos Found No No No No No No ____i> Type{s)& Chrysotile r ------ CD Percentage(s) of Amosite —m Asbestos Found Crocidolite 2 ------ C Other — g2 (Actinolite, Tremolite, Anthophyllite) ----- 2 m Total Asbestos Found ND ND ND ND ND ND 2 ----- -I Other Fiberglass 70 35 1>

Fibrous Cellulose 90 <1.0 70 85 90 Materials Synthetic Non-Fibrous Carbonates Materials Silicates Binder 30 10 65 30 15 10 Location; 8 Floor Plenum 7 Floor Plenum 6 Floor Plenum 5 Floor Plenum 4 Floor Plenum 3 Floor Plenum Dust/Debris Dust/Debris DusVDebris DusVDebris Dust/Debris Dusl/Debris Room 805 Room 702 Room 611 Room 503 Room 404 Corridor INC = Inconclusive ND = None Detected o NG = None Given____________________________________________________________________________________________________________________ UI I-*- CT. H “ Residual weight of sample is <1.0% of original subsample weight; no further analysis is necessary. UI UI Polarized light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before CD to I-' (—1 -J 2 this material can be considered or treated as non-asbestos-containing, confirmation must be made by quantitative transmission electron microscopy. CD o 1) The results represented in this test report relate only to the samples tested. G) o o 2) This test report shall not be reproduced except in full, without the written approval of Taylor Environmental Group, Inc. I o o TWs report must not be used by the client to claim product endorsement by UVLAP or any agency of the US Government. Page 2 of 3 G) UI CO LO O 130A JERICHO TPKE., FLORAL PARK, NY 1 1001 -PHONE (516| 35B-2955 -FAX (516) 358-1780 to

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418778Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →