Bulk asbestos test report, Trinity Place project, Dec 2001

Machine-extracted title · confidence 54%

Bulk asbestos testing report for Trinity Place construction, with multiple lab numbers and dates.

NYC-WTC_000324397–000324398
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Bulk Asbestos Test Report Taylor environmental group; inc. Test MeUiod; ERA GOO/R-93/116 RAP #10928 Client: NYC School Construction Authority Date Received: 12/21/01 30-30 Thomson Avenue ________ Date Analyzed: 12/21/01 Long Island City, N.Y. 11101 Analyst; Re: 90 Trinity Place LLW#: Report Ref: M894-14e30

Laboratory Number 35484 35485 35486 35487 35488 35489 Sample Reference 01 02 03 04 05 06 Gross Sample Color Off White Oft White Off White Gray Gray Gray Appearance Homogeneous Yes Yes Yes Yes Yes Yes Fibrous Yes Yes Yes Yes Yes Yes Asbestos Found No No No No No No Type(s) & Chrysotile Percentage(s) of Amosite Asbestos Found Crocidolite Other (Actinolite, Tremolite, Anthophyllite) Total Asbestos Found ND ND ND ND ND ND Other Fiberglass 10 70 Fibrous Cellulose 80 40 80 30 10 85 Materials Synthetic Non-Fibrous Carbonates Materials Silicates Binder 20 60 20 60 20 15 Location: 14 Floor Plenum 13 Floor Pleiiuiri 12 Floor Plciium 11 Floor Plenum 10 Floor Plenum 9 Floor PlGnuin Dust/Debris DusiyDebris Dust/Debris Dust/Debris DusLDebris DusiyDebris Room 1403 Room 1306 Room 1205 Room 1105 Room 1005 Room 906 INC = Inconclusive ND = None Detected NG = None Given___________________________________________________________________________________________________________________________ o '* Residual weight of sample is <1.0% of original subsarnple weight; no further analysis is necessary. * Polarized light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before hC I this material can be considered or treated as non-asbestos-containing, confirmation must be made by quantitative transmission electron microscopy. K) 1) The results represented in this test report relate only to the samples tested. I 2) Ttiis lest report shall not be reproduced except in full, without the written approval of Taylor Environmental Group, Inc,

1° This report must not be used by the client to claim product endorsement by NVLAP or any agency of ttie US Government, Page 1 of 4 o w I 30A JERICHO TPKE., FLORAL PARK. NY I 1001 ■ PHONE (5 16) 358-2955 - FAX (516) 358-1/80 co CD

hp.

NYC-WTC_000324397

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324397Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →