Bulk asbestos test report, Trinity Place project, Dec 2001

Machine-extracted title · confidence 54%

Bulk asbestos testing report for Trinity Place construction, with multiple lab numbers and dates.

NYC-WTC_000324397–000324398
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

vuu lei [Actinolite, Tremolite, Anthophyllite) Total Asbestos Found ND ND ND ND ND ND Other Fiberglass 70 35 Fibrous Cellulose 90 <1.0 70 85 90 Materials Synthetic Non-Fibrous Carbonates Materials Silicates Binder 30 10 65 30 15 10 Location: 8 Floor Plenum 7 Floor Plenum 6 Floor Plenum 5 Floor Plenum 4 Floor Plenum 3 Floor Plenum Dust/Debrls Dust/Debris Dusl/Debris Dust/Debris Dusb'Debris Dust/Debris Room 805 Room 702 Room 611 Room 503 Room 404 Corridor INC = Inconclusive ND = None Detected NG - None Given____________ ■* Residual weight of sample is <1.0% of original subsample weight; no further analysis is necessary. Polarized light microscopy is not consistently reliable in detecting asbestos in flooi coveiings and similar non-friable organically bound materials Before this material can be considered or heated as non-asbestos-containing, confirmation must be made by quantitative transmission electron microscopy 1) The results represented in this test report relate only to Ihe samples tested 2) This test report shall not be reproduced except in lull, without the written apptoval of Taylor Environmental Group, Inc.

This repoit iiiusi not be used by the client Io claim product siidorsetiiciil By .^IVLAP or any agency of the US Government. Page 2 of 4

130A JERICHO IPKE , FLORAL PARK. NY 1 1001 ■ PHONE (516) 358-2955 - FAX (516) 358 1780

Binder 10 Location: 2 Floor Plenum Dust/Debris Corridor INC = Inconclusive ND = None Detected NG = None Given____________________ ___________________ __________________ J___________________ ___________________ ________________

O ** Residual weight of sample is <1.0% of original subsample weight, no further analysis is necessary, * Polarized light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before 1-1 Ki this material can be considered or treated as non-asbestos-containing, confirmation must be made by quantitative transmission electron microscopy. I to 1) The results represented in this test report relate only to the samples tested 12 2) This test report shall not be reproduced except in full, without the written approval of Taylor Environmental Group, Inc.___ O o This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. Page 3 of 4 1° o 1 BOA JERICHO TPKE , FLORAL PARK, NY I 100 I • RHONE (516) 358 2955 - FAX (516) 358-1780 CO

NYC-WTC_000324398

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324398Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →