z z o o io Table 2 Exterior Netting - Lead Microvacuum Sampling Results co

I ■D o Lead Wipe (ICP 601 OB) c o CT o o' tn LMDC ■D ro o ro 130 Liberty Street 3. 03 CJ> New York, New York o o April 22, 2005 o c 3 Lead Lead CD

Sample ID Lab Sample ID Sample Date Sample Type Floor Location (ug/ft2) (ug/m2)

1-Lead-020805 010500464-0001 2/8/2005 Wipe 1 South East corner - catwalk 603 6,491 2-Lead-020805 010500464-0002 2/8/2005 Wipe 1 North East corner - catwalk 649 6,986 3-Lead-020805 010500464-0003 2/8/2005 Wipe B North side basement level "B" 689 7,416 4-Lead-020805 010500464-0004 2/8/2005 Wipe A North side street level "A" 613 6,598 5-Lead-020805 010500464-0005 2/8/2005 Wipe 1 Above loading BwBT S/W - catwalk 360 3,875 1-Lead-FL40-033005 010501109-0001 3/30/2005 Wipe 40 West side between columns 6 and 7 223 2,400 2-Lead-FL36-033005 010501109-0002 3/30/2005 Wipe 36 West side between columns 6 and 7 173 1,862 3-Lead-FL32-033005 010501109-0003 3/30/2005 Wipe 32 West side between columns 6 and 7 236 2,540 4-Lead-FL16-033005 010501109-0004 3/30/2005 Wipe 16 West side between columns 6 and 7 204 2,196 5-Lead-FL16-033005 010501109-0005 3/30/2005 Wipe 16 West side between columns 6 and 7 185 1,991 6-Lead-FL8-033005 010501109-0006 3/30/2005 Wipe 8 West side between columns 6 and 7 948 10,204

uq/ft2 Arithmetic Mean 444 May 2003 Benchmark^ 25 April 2003 Background Assessment^ 1.78 September 2002 WTC Indoor Assessment^ Tier I >40 Tier II 40 to 25 (or background) o Tier III <25 (or background) H

I K J - Value is estimated due to a high recovery in the quantitation limit standard. to

s O References: o World Trade Center Indoor Environment Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contamir o I o Potential Concern (COPC) Committee. United States Environmental Protection Agency, May 2003. o 2 to World Trade Center Background Study Report, Interim Final. United States Environmental Protection Agency, Region 2, April 2003. to 3 World Trade Center Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contaminants of P CO co Concern (COPC) Committee of the World Trade Center Indoor Air Taskforce Working Group. Peer Review Draft, September 2002. ho o TRC Environmental Corporation

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000452726Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000422125

Summary report for LMDC Plaza sampling at 130 Liberty Street, prepared by TRC Environmental Corp., April 2005.

Similar indexed content

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →