LMDC sampling summary, LMDC Plaza, Apr 2005

Machine-extracted title · confidence 34%

LMDC sampling summary for Lower Manhattan Development Corporation site at LMDC Plaza; April 2005.

NYC-WTC_000452708–000452732
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z z o o Table 1 co g o Exterior Netting - Asbestos Microvacuum Sampling Results I Asbestos Microvacuum (ASTM D5755-03) ■D o c o CT o o' cn LMDC ■D ro o ro 130 Liberty Street 3. cn 03 New York, New York April 22, 2005 o o o c 3 Sample Sample ASBESTOS CD

Sample ID Lab Sample ID Date Type Floor Location (structures/cm^)

1-021005 MICRO VAC-S/E CATWALK-KD 030503485-0001 2/10/2005 MV 1 South East corner - catwalk 439,000 2-021005 MICRO VAC-N/E CATWALK-KD 030503485-0002 2/10/2005 MV 1 North East corner - catwalk 439,000 3-021005 MICRO VAC-NORTH BSMT "B"-KD 030503485-0003 2/10/2005 MV B North side basement level "B" 8,360 4-021005 MICRO VAC-NORTH BSMT "A"-KD 030503485-0004 2/10/2005 MV A North side street level "A" 23,000 5-021005 MICRO VAC-S/W CATWALK-KD 030503485-0005 2/10/2005 MV 1 South West corner - catwalk 96,100 6-021005 MICRO VAC-BLANK-KD 030503485-0006 2/10/2005 MV BLANK Blank 1-ASB-FL40-033005 030508387-0001 3/30/2005 MV 40 West side between columns 6 and i <627 2-ASB-FL36-033005 030508387-0002 3/30/2005 MV 36 West side between columns 6 and i 14,700 3-ASB-FL32-033005 030508387-0003 3/30/2005 MV 32 West side between columns 6 and i <1260 4-ASB-FL16-033005 030508387-0004 3/30/2005 MV 16 West side between columns 6 and i <1570 5-ASB-FL8-033005 030508387-0005 3/30/2005 MV 8 West side between columns 6 and i 3,150 6-ASB-BL-033005 030508387-0006 3/30/2005 MV West side between columns 6 and i Blank

str/cm2 Arithmetic Mean (1/2ND) 102,504 May 2003 Benchmark^ n/a April 2003 Background Assessment^ 6,192 September 2002 WTC Indoor Assessment^ Q Tier I >30,000 H Tier II >30,000 to background I K Tier III Background

s o References: o World Trade Center Indoor Environment Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contaminan o I Potential Concern (COPC) Committee. United States Environmental Protection Agency, May 2003. o o 2 co World Trade Center Background Study Report, Interim Final. United States Environmental Protection Agency, Region 2, April 2003. 3 World Trade Center Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contaminants of Pote CO co Concern (COPC) Committee of the World Trade Center Indoor Air Taskforce Working Group. Peer Review Draft, September 2002. TRC Environmental Corporation

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000452725Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000422125

Summary report for LMDC Plaza sampling at 130 Liberty Street, prepared by TRC Environmental Corp., April 2005.

Similar indexed content

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →