NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 25 pages

LMDC Sampling Summary, Apr 2005

Machine-extracted title · confidence 32%

Summary report for LMDC Plaza sampling at 130 Liberty Street, prepared by TRC Environmental Corp., April 2005.

NYC-WTC_000422125–000422149
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 2 Exterior Netting - Lead Microvacuum Sampling Results Lead Wipe (ICP 601 OB)

LMDC 130 Liberty Street New York, New York April 22, 2005

Lead Lead Sample ID Lab Sample ID Sample Date Sample Type Floor Location (ug/ft2) (ug/m2)

1-Lead-020805 010500464-0001 2/8/2005 Wipe 1 South East comer - catwalk 603 6,491 2-Lead-020805 010500464-0002 2/8/2005 Wipe 1 North East corner - catwalk 649 6,986 3-Lead-020805 010500464-0003 2/8/2005 Wipe B North side basement level "B" 689 7,416 4-Lead-020805 010500464- 55S4 2/8/2005 Wipe A North side street level "A" 613 6,598 5-Lead-020805 010500464-0005 2/8/2005 Wipe 1 Above loading door S/W - catwalk 360 3,875 1-Lead-FL40-033005 010501109-0001 3/30/2005 Wipe 40 West side between columns 6 and 7 223 2,400 2-Lead-FL36-033005 010501109-0002 3/30/2005 Wipe 36 West side between columns 6 and 7 173 1,862 3-Lead-FL32-033005 010501109- Baal3 3/30/2005 Wipe 32 West side between columns 6 and 7 236 2,540 4-Lead-FL16-033005 010501109-0004 3/30/2005 Wipe 16 West side between columns 6 and 7 204 2,196 5-Lead-FL16-033005 010501109-0005 3/30/2005 Wipe 16 West side between columns 6 and 7 185 1,991 6-Lead-FL8-033005 010501109-0006 3/30/2005 Wipe 8 West side between columns 6 and 7 948 10,204

O uq/ft2 Arithmetic Mean 444 1^ May 2003 Benchmark^ 25 o m April 2003 Background Assessment^ 1.78 September 2002 WTC InESH r Assessment^ o Tier I >40 J] □0 Tier II 40 to 25 (or background) Tier III <25 (or background) 'o > z J - Value is estimated due to a high recovery in the quantitation limit standard.

s c □0 References: World Trade Center Indoor Environment Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contamir Potential Concern (COPC) Committee. United States Environmental Protection Agency, May 2003. 1"° o 2 World Trade Center Background Study Report, Interim Final. United States Environmental Protection Agency, Region 2, April 2003. o 3 o World Trade Center Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contaminants of P o tn Concern (COPC) Committee of the World Trade Center Indoor Air Taskforce Working Group. Peer Review Draft, September 2002. r\o 00 co TRC Environmental Corporation

NYC-WTC_000422143

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000422143Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →