NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 25 pages

LMDC Sampling Summary, Apr 2005

Machine-extracted title · confidence 32%

Summary report for LMDC Plaza sampling at 130 Liberty Street, prepared by TRC Environmental Corp., April 2005.

NYC-WTC_000422125–000422149
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

130 Liberty Street -Building Netting April 25, 2005 Supplemental Investigation Summary Page 8

World Trade Center Background Study Report Interim Final (April 2003). The highest concentrations of asbestos were identified in the first and second floors, fifth floor mechanical room, and the 40‘*'/4L‘ floor mechanical room. Asbestos was detected in dust at concentrations in excess of 6,192 structures/cm^ in 24 of the 31 floors sampled by TEM analysis (77%). The samples containing asbestos ranged from a minimum concentration of less than 891 structures/cm“ (from Floors 5, 24, 25, 28, 34, and 41) to a maximum concentration of 4,879,200 structures/cm^ (from Floor 2). These results are generally greater than the netting investigation results.

3.2 Lead

Ten wipe and one duplicate sample was collected from street level and at higher elevations designated by the Building floor as detailed in Section 3.1. The sample results ranged from 173 ug/ft^ to 948 ug/ft^ with an arithmetic average of 444 ug/ft^. All ten samples exceeded the Tier 1 Indoor Assessment value of 40 ug/ft^. Sample results are provided in the attached Table 2.

A limited data validation was performed the samples in accordance with the USEPA Contract Laboratory Program National Functional Guidelines for Inorganic Data Review (July 2002). In general, the data appear to be valid as reported and may be used for decision-making purposes.

According to the Initial Building Characterization Report, there was significant variation in the lead testing results collected from the Building dust samples. Lead was detected in 122 of 125 samples tested. Lead results of samples collected above the plenum ranged from 350 ug/m^ (32.52 ug/ft^) to 10,900 ug/m^ (1,012.6 ug/ft^). Lead results from samples collected below the plenum ranged from 150 ug/m^ (13.92 ug/ft^ - in Zone 3) to 101,000 ug/m^ (9,383.2 ug/ft^ - in Zone 1). These results are generally greater than the results of this investigation.

3.3 Silica

Ten wipe and one duplicate sample was collected from street level and at higher elevations designated by the Building floor as detailed in Section 3.1. The silica sample results ranged from 0.1 milligrams per square foot (mg/ft^) to 1,238 mg/ft^ with an c arithmetic average of 201.3 mg/f?. Sample results are provided in the attached Table 3. CD E 3 o A limited data validation was performed the samples in accordance with the USEPA o Q Contract Laboratory Program National Functional Guidelines for Inorganic Data TO ■c co o CM Q_ CM o O Z O 3 O 0. o' O) O 6 z CITY_DEP_WORBY_CANNATA_SUBP_000052825 z

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000422134Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →