NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
adjusted to the desired sampling value, and the flow rate observed on the rotometer (or
bubble meter) will be verified as constant for a minimum of 20 seconds. Flow rates will
be recorded on Field Sampling Data Sheets or an equivalent field logbook. To initiate
sample collection, the aluminum foil is removed from the pre-cleaned cartridge assembly
(foil returned to the jar for later use) and the cartridge is attached to the pump
with flexible tubing. The sampling assembly is positioned with the intake downward or in
a horizontal position. The samplers are fastened to a location (i.e., on a tripod) near
the individual’s breathing zone at least 30 meters from any obstacle from air flow with
the PUF intake and at least 1 to 2 meters above ground level. After the PUF cartridge is
correctly inserted and positioned, the power switch is turned on, the elapsed time meter is
activated, sampling begins, and the start time is recorded on the Field Data Sheet or
equivalent field logbook. At the conclusion of each sampling period, the power switch is
turned off, stop time recorded, the PUF cartridge is removed from the pump and wrapped
with its original aluminum foil, the Teflon® end caps are replaced on the cartridge, and it
is placed back into its original sealed and labeled container, placed in an ice chest under
ice (< 4°C), and transported to the analytical laboratory for processing. Equipment and
supplies utilized with this sampling approach are as follows:
• Low-Volume, Continuous Flow Personal Sampling Pump - SKC Leland Legacy
Personal Monitor and Sampling Pump (or equivalent): 5 to 15 1pm.
• Battery Pack - Rechargeable lithium-ion battery pack (or equivalent) compatible
with the personal sampling pump.
• Sampling Cartridge - Constructed from a 20-mm (l.D.) by 10-cm borosilicate
glass tube drawn down to a 7-mm (O.D.) open connection for attachment to the
pump by way of flexible tubing.
• Polyurethane Foam (PUF) Plugs - Cut into a cylinder, 22-mm (l.D.) and 7.6-cm
long, fitted under slight compression inside the cartridge. Polycthcr type (density
0.0225 g/cm3). Plugs should be slightly larger in diameter than the internal
diameter of the cartridge. Pre-extracted PUF plugs and glass cartridges may be
obtained commercially.
• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate
seal to prevent pre- or post- sampling exposure to other potential sources of the
target analytes.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will
insert the PUF plug into the glass sample cartridge during prc-sampling
preparation.
• Flexible Tubing - Used to connect the cartridge assembly to the sampling pump.
• Sample Cartridge Shipping Containers - The analytical laboratory will provide
individually labeled containers that will be used to transport the sample cartridges
to the field location and back to the laboratory for analysis. This will include
aluminum foil wrapped around the cartridge and a glass jar large enough to hold
the cartridge.
• White Cotton Gloves - For handling the cartridges.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.