period, the sample is recovered from the sampling train by placing the filter inside the
glass cartridge. The glass cartridge is then wrapped with aluminum foil and it is placed
back into its original shipping container, labeled, and transported to the analytical
laboratory for processing. Equipment and supplies utilized with this sampling approach
are as follows:
• High-Volume Sampler - General Metals Works (GMW) PS-1 (or equivalent),
capable of pulling ambient air through the filter/adsorbent cartridge sampling train
at a flow rate of 200- 300 1pm to obtain a total sample volume of 288-432 ma over
a 24-hour period . • High-Volume Sampler Calibrator - Capable of providing
multipoint resistance for the highvolume sampler.
• Quartz Fiber Filters - 102 millimeter (102-mm) bindless quartz micro fiber filter,
Whatman International Ltd, QMA-4 (or equivalent), provided by the laboratory,
pre-cleaned and weighed.
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal
diameter of the cartridge.
• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate
seal to prevent pre- or post- sampling exposure to other potential sources of the
target analytes.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will
insert the PUF plug into the glass sample cartridge during pre-sampling
preparation. • Sample Cartridge Aluminum Shipping Containers - The analytical
laboratory will provide individually labeled containers that will be used to
transport the sample cartridges to the field location and back to the laboratory for
analysis.
• 0-100” Magnehelic Gage.
• White Cotton Gloves - For handling the filters and cartridges.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.
10.2.6 Polychlorinated Biphenyls (PCBs)
Ambient air samples will be collected using a low-volume SKC Leland Legacy
personal sampling pump equipped with a glass cylinder containing a polyurethane
sorbent (i.e., PUF plug) for the collection of gas and particulate phase PCBs. Samples
will be collected at a flow rate of five liters per minute (5 1pm) with a sampling period of
approximately 24 hours for a resulting total air volume of approximately 7.2 cubic meters
(7.2 ma). The PUF (Polyurethane Foam) sampler is an air sampling system designed to
trap airborne organic vapors. The PUF sampler is equipped with a low-volume pump.
This feature is designed to permit the motor to operate at low sampling flow rates for
extended periods without motor failure from overheating. The sampling cartridge is
constructed of borosilicate glass, is filled with the PUF plug, and is connected to the
sampling pump by way of flexible tubing. Pump flow rates of each personal sampling
pump, with a representative sampler in line, will be measured before and after sample
collection. The pump will be run for 10 minutes prior to checking the flow rate. A
suitable rotometer (or bubble meter) will be connected to the filter inlet, the flow screw