Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
> 5xQL
Standard 1/10 samples Percent Recalibrate, Accuracy/Bias
Additions recoveries 85- reanalyze
115% and/or qualify
data.
Breakthrough 1/location during Back half trap Qualify data Accuracy/Bias
Check background phase results must be and/or change
< 2% of front subsequent
half trap sampling
results or < 5 volumes.
ng per trap
Field/Trip 1/day Mercury must Reclean, Accuracy/Bias-
Blanks be < 15 ng per reanalyze Contamination
trap and/or qualify
data.________
Media 1/batch Mercury must Reclean and Accuracy/Bias-
Cleaning be < 15 ng per retest media. Contamination
Verification trap
Check
Data NA Field 80%; NA Data
Completeness Laboratory 95 Completeness
Check
' Collection of Field Duplicates and Field Spikes will be alternated on a weekly basis.
Reanalyze: refers to analysis of same digestate.
Tab/e8-7. Measurement Performance Cr/ten'a Table-S/tica by XRD
QC Sample or Frequency Measurement Corrective DQI
Activity Performance Action
Criteria
Field 1/week *RPD < 40 Assess Precision-
Duplicates when positive laboratory Overall
results for both precision; and
samples are > /or qualify
5xQL data.
*No situation
where one
result is
detected at >
5x QL and
other result is
not detected
Laboratory 1/batch RPD < 20 if Reanalyze ad Precision
Duplicates results are > 5x qualify data.
detection limits
46
CITY_21MC100_003237450
NYC-WTC_000447479
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000447479Source: NYC Law Department, mirrored locally