NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

Environmental Community Air Monitoring Plan

Machine-extracted title · confidence 50%

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

NYC-WTC_000447434–000447562
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Slreet/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

> 5xQL Standard 1/10 samples Percent Recalibrate, Accuracy/Bias Additions recoveries 85- reanalyze 115% and/or qualify data. Breakthrough 1/location during Back half trap Qualify data Accuracy/Bias Check background phase results must be and/or change < 2% of front subsequent half trap sampling results or < 5 volumes. ng per trap Field/Trip 1/day Mercury must Reclean, Accuracy/Bias- Blanks be < 15 ng per reanalyze Contamination trap and/or qualify data.________ Media 1/batch Mercury must Reclean and Accuracy/Bias- Cleaning be < 15 ng per retest media. Contamination Verification trap Check Data NA Field 80%; NA Data Completeness Laboratory 95 Completeness Check ' Collection of Field Duplicates and Field Spikes will be alternated on a weekly basis. Reanalyze: refers to analysis of same digestate.

Tab/e8-7. Measurement Performance Cr/ten'a Table-S/tica by XRD QC Sample or Frequency Measurement Corrective DQI Activity Performance Action Criteria Field 1/week *RPD < 40 Assess Precision- Duplicates when positive laboratory Overall results for both precision; and samples are > /or qualify 5xQL data. *No situation where one result is detected at > 5x QL and other result is not detected Laboratory 1/batch RPD < 20 if Reanalyze ad Precision Duplicates results are > 5x qualify data. detection limits

46

CITY_21MC100_003237450

NYC-WTC_000447479

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447479Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000440780

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →