project-specific target analytical sensitivity of less than 0.0009 fibers/cms.
11.1.2.4 Metals Analysis by SW-846 Method 6020A
Metals analysis will be performed using SW-846 Method 6020A with the
following modifications:
• Samples will be digested using nitric acid as per 40 CFR Part 50 Appendix J, not
a mixture of nitric and hydrochloric acid. Sample digestion will be performed
using a hotplate or Modblock digestion procedure.
• Initial ICP/MS instrument calibration will be performed using a blank and a
single-point standard.
• The routine calibration procedure will not include the analysis of a High
Standard Verification (HSV) standard. Calibration will be verified with the CCB
and CCV.
• The laboratory will perform the metals analysis by scanning the selected ion, not
scanning all ions from 5-250 amu.
• The internal standard mixture used by the laboratory will include Li, Ge, In, Tm,
and Bi.
11.1.2.5 PCB Analysis
PCB extracts for Aroclor analysis will be concentrated to a final volume of 5 mL. If the
total PCB analysis yields a result which exceeds the USEPA Site-Specific Trigger Level,
a further congener analysis will be performed on the same extract to confirm the total
PCB concentration. This analysis will also be performed using GC/ECD; however,
further QC analyses for the PCB congener analysis will not be required assuming the
results of the PCB Aroclor QC measurements (Table 8-4) demonstrate adequate accuracy
and precision of the sample extract analysis.
11.2 Analytical Quality Control
Tables 8-2 through 8-10 summarize the QC procedures checks, and samples, and their
respective acceptance limits for each fixed laboratory analytical parameter that will be
used during the project.
11.2.1 Field Analytical QC
Calibration procedures discussed in Section 13.2.1 will be adhered to for field analyses
of gaseous mercury in order to ensure the accuracy of sample measurements.
11.2.2 Fixed Laboratory QC
All required QC checks and QC samples and the associated QC acceptance limits are
75