NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 134 pages

Environmental Community Air Monitoring Plan, Greenwich/Thames

Machine-extracted title · confidence 31%

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

NYC-WTC_000446622–000446755
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - February 1, 2006

Method Blanks 1/prep batch Mercury must Reclean, Accuracy/Bias- be < 15 ng per reanalyze Contamination trap and/or qualify data Calibration 1/10 samples Mercury must Reclean, Accuracy/Bias- Blanks be < 50 pg reanalyze Contamination and/or qualify data

Field Spikes 4 Percent Reanalyze Accuracy/Bias spikes/background recoveries 80- and/or qualify and Precision phase followed by 120%; % RSD 1 spike/every other < 30 in week background phase Duplicate Every sample, RPDs must be Reanalyze Precision Injections blank, QC <10 when and/or qualify positive results for both injections are > 5xQE Triplicate Every 10 samples % RSD < 10 Reanalyze Precision Injections when positive and/or qualify results for all injections are > 5xQE Standard 1/10 samples Percent Recalibrate, Accuracy/Bias Additions recoveries 85- reanalyze 115% and/or qualify data. Breakthrough 1/location during Back half trap Qualify data Accuracy/Bias Check background phase results must be and/or change < 2% of front subsequent half trap sampling results or < 5 volumes. ng per trap Field/Trip 1/day Mercury must Reclean, Accuracy/Bias- Blanks be < 15 ng per reanalyze Contamination trap and/or qualify data.

49

CITY_21MC100_0 03239902

NYC-WTC_000446670

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000446670Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000448085

Title/approval sheet for Environmental Community Air Monitoring Program and Greenwich/Thames Plan.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →