Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
Field 1/Week *RPD < 40 Assess Precision-
Duplicates when positive laboratory Overall
results for both precision; and
samples are > /or qualify data.
5x QL
*No situation
where one
result is
detected at > 5x
QL and other
result is not
detected
Surrogates Every sample, Percent Reanalyze if Accuracy/Bias
blank, QC recoveries both surrogates
TCMX and outside limits
DBCP 60- or one < 10%,
120% and /or qualify
data.
Method Blanks 1/prep batch No target Reclean, Accuracy/Bias-
compounds > reanalyze, Contamination
QL and/or qualify
data.
Field/Trip 1/day No target Reclean, Accuracy/Bias-
Blanks compounds > reanalyze, Contamination
QL and/or qualify
data.
PUF Media 1/batch cleaned No target Reclean batch Accuracy/Bias-
Cleaning compounds > Contamination
Verification QL
Check
Laboratory 1/prep batch Percent Determine Accuracy/Bias
Control Sample recoveries 70- cause of
130% problem
reanalyze
and/or qualify
data.
Laboratory 1/prep batch Percent Determine Accuracy/Bias
Control Sample recoveries 70- cause of and Precision
Duplicate 130% RPD < problem
50 reanalyze
and/or qualify
data.
Dual Column Every sample, %D between Narrate/Flag Precision
Analysis blank, QC columns < 25 data.
46
CITY_21MC100_0 03239899
NYC-WTC_000446667
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000446667Source: NYC Law Department, mirrored locally