Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
Thames Street Environmental Community Air Monitoring Program and Waste
Management Plan are designed to produce data of the quality necessary to achieve PQOs
and meet or exceed the minimum standard requirements for field and analytical methods.
The overall QA objective is to develop and implement procedures for field sampling,
chain-of-custody, laboratory analysis, and reporting which will provide results that are
scientifically valid, and the levels of which are sufficient to meet PQOs.
Specific procedures for sampling, chain of custody, laboratory and field instruments
calibration, laboratory analysis, reporting of data, internal quality control, preventative
maintenance of field and laboratory equipment, and corrective action are described in
other sections of this QAPP. The purpose of this section is to state the specific, required
QA objectives for accuracy, precision, representativeness, completeness, sensitivity,
selectivity, and comparability. Measurement performance criteria for precision,
accuracy/bias, representativeness, completeness, sensitivity, quantitation limits,
selectivity, and comparability have been established for each parameter and are
summarized in Tables 8-2 through 8-10. These measures of performance are also referred
to as Data Quality Indicators (DQIs) and are discussed in detail below.
8.2.1 Precision
Precision is the agreement among a set of replicate measurements without consideration
of the “true” or accurate value: i.e., variability between measurements of the same
material for the same analyte. Precision is measured in a variety of ways including
statistically, such as calculating variance or standard deviation. The results of the
background phase will be used to monitor overall precision (field and laboratory) and
will be included as Attachment B to the QAPP, when available.
Field Precision Objectives Field precision is assessed through the collection and
measurement of collocated and/or duplicate samples (also called field duplicates) which
consist of a second sample in addition to the original field sample. In general, field
duplicates will be collected at a frequency of once per week per analytical parameter for
the air sampling aspect of this project. Precision will be measured through the calculation
of relative percent difference (RPD). Field duplicates for the waste characterization
purposes will be collected at a frequency of once per every 10 samples per matrix per
analytical parameter (with exception of corrosivity and ignitibility). The resulting
information will be used to assess sample homogeneity, spatial variability at the site,
sample collection reproducibility, and analytical variability. Field duplicate RPDs must
be <40 for air samples. Field duplicate RPDs must be <50 for solid matrices and <30 for
aqueous matrices for the waste characterization aspects of this project. Field precision
will be maintained by utilizing experienced/trained sampling crews and conducting field
audits. In addition, during the background phase of the program, the precision of the
mercury sampling and analysis method will be tested. Ambient air samples will be
collected at one location using a series of four iodated carbon traps prespiked (50 ng/trap)
with mercury. These samples will provide data on the precision of the method under
actual field sampling conditions. Following the background phase, one field spike will be
performed every other week, alternating with the field duplicates.