Chain-of-custody for Air Monitoring Plan, Greenwich/Thames

Machine-extracted title · confidence 42%

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

NYC-WTC_000446145–000446278
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - February 1, 2006

Thames Street Environmental Community Air Monitoring Program and Waste Management Plan are designed to produce data of the quality necessary to achieve PQOs and meet or exceed the minimum standard requirements for field and analytical methods. The overall QA objective is to develop and implement procedures for field sampling, chain-of-custody, laboratory analysis, and reporting which will provide results that are scientifically valid, and the levels of which are sufficient to meet PQOs. Specific procedures for sampling, chain of custody, laboratory and field instruments calibration, laboratory analysis, reporting of data, internal quality control, preventative maintenance of field and laboratory equipment, and corrective action are described in other sections of this QAPP. The purpose of this section is to state the specific, required QA objectives for accuracy, precision, representativeness, completeness, sensitivity, selectivity, and comparability. Measurement performance criteria for precision, accuracy/bias, representativeness, completeness, sensitivity, quantitation limits, selectivity, and comparability have been established for each parameter and are summarized in Tables 8-2 through 8-10. These measures of performance are also referred to as Data Quality Indicators (DQIs) and are discussed in detail below.

8.2.1 Precision

Precision is the agreement among a set of replicate measurements without consideration of the “true” or accurate value: i.e., variability between measurements of the same material for the same analyte. Precision is measured in a variety of ways including statistically, such as calculating variance or standard deviation. The results of the background phase will be used to monitor overall precision (field and laboratory) and will be included as Attachment B to the QAPP, when available.

Field Precision Objectives Field precision is assessed through the collection and measurement of collocated and/or duplicate samples (also called field duplicates) which consist of a second sample in addition to the original field sample. In general, field duplicates will be collected at a frequency of once per week per analytical parameter for the air sampling aspect of this project. Precision will be measured through the calculation of relative percent difference (RPD). Field duplicates for the waste characterization purposes will be collected at a frequency of once per every 10 samples per matrix per analytical parameter (with exception of corrosivity and ignitibility). The resulting information will be used to assess sample homogeneity, spatial variability at the site, sample collection reproducibility, and analytical variability. Field duplicate RPDs must be <40 for air samples. Field duplicate RPDs must be <50 for solid matrices and <30 for aqueous matrices for the waste characterization aspects of this project. Field precision will be maintained by utilizing experienced/trained sampling crews and conducting field audits. In addition, during the background phase of the program, the precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four iodated carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the precision of the method under actual field sampling conditions. Following the background phase, one field spike will be performed every other week, alternating with the field duplicates.

40

CITY_21MC100_007121327

NYC-WTC_000446184

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000446184Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000448085

Title/approval sheet for Environmental Community Air Monitoring Program and Greenwich/Thames Plan.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

Compare copies and versions →