WTC Indoor Air Monitoring - Sampling and Analytical Procedures Analytical Media Sampling Points Sampling Method Proposed Sampling Vulnerability/Practicality Parameters

"This test method does not describe procedures or techniques required to evaluate the safety or habitability of buildings with asbestos­ Asbestos Microvac ASTM 5755-95 containing materials, or compliance with federal, state, or local regulations or statutes. It is the user's responsibility to make these determinations." (Section 5.1.1 of method 5755-95)

Lead Microvac ASTM 5755-95** Carpets, fabric furniture or Porous Soft After speaking with several people in HQ and RTP, it does not appear drapery in areas of activity Still checking on methods. Reached surfaces there are standardized methods for the collection of these parameters, (living rooms, family rooms) Dioxins out to RTP and HQ. Waiting for rather many of the methods being used today are research and additional information development procedures.

PAHs

Silica

See the comment for asbestos. Samples will be combined with the MMVF Microvac ASTM 5755-95 asbestos sampling.

"This test method does not describe procedures or techniques required to evaluate the safety or habitability of buildings with asbestos­ Wipe ASTM D 6480-99 or Asbestos containing materials, or compliance with federal, state, or local Microvac ASTM 5755-95 regulations or statutes. It is the user's responsibility to make these determinations." (Section 5.1.1 of method 5755-95) Horizontal surfaces of tables Non-porous or counters and barefloors, Lead NIOSH 9100 None known, wipe sampling has been legally defended. Hard ceilings and walls in areas of surfaces activity (living rooms, family Dioxins ASTM D 6661 -01 rooms) PAHs ASTM D 6661 -01

Silica See comment for silica above. See comment for silica above.

Wipe ASTM D 6480-99 or Same as asbestos microvac. Samples will be combined with the MMVF Microvac ASTM 5755-95 asbestos sampling.

Air pump operated at lOL/min for 8 hours to achieve the PIC wkgroup Asbestos NIOSH 7400 detection limits

O Air pump operated at lOL'min for 8 hours to achieve the PIC wkgroup Lead NIOSH 7300 Areas of known activity (living detection limits H Indoor Air rooms, family rooms) Air pump operated at 2.5L/min for 8 hours to achieve the PIC wkgroup Silica NIOSH 7500 detection limits

S Assumed that it behaves the same as asbestos, samples will be o MMVF NIOSH 7400 combined with the asbestos sampling. o o Io NOTE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh the sample wipe or cassette prior to performing the analysis. o co to co o to co co

NYC-WTC_000438264

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000438264Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Sampling procedures for WTC indoor monitoring

NYC-WTC_000204871

Document outlining analytical procedures and standards for collecting asbestos and lead samples from indoor surfaces during World Trade Center cleanup studies.

Similar indexed content

Compare copies and versions →