Samples will be collected from 14 buildings, 3 units within each building (2 residences and 1 common area).

14 buildings x 3 units per building = 42 units

32 samples/unit x 42 units = 1344 samples + 134 QC samples = 1478 samples

ATTACHMENT 2

WTC Indoor Air Monitoring - Sampling and Analytical Procedures Analytical Media Sampling Points Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed Parameters

Carpets, fabric furniture or Settled drapery in areas of activity This is a micro vacuuming method. Three collocated samples will Dust Asbestos ASTM D 5755-95 ASTM D 5755-95 (living rooms, family be collected from each location. Porous ________ rnnmR)________ Soft This is a micro vacuuming method. Three collocated samples will surfaces Lead ASTM E 1973-99 SW-846 6010B be collected from each location.

Horizontal surfaces of tables or counters and Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe) bare floors, ceilings and W3lls in 3rQ3s of sctivity (living rooms, family Wipe Samples SW-846 6010B Lead ASTM E 1728 Settled rooms) Dust Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 Non-porou s Hard surfaces PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C

Silica ASTM E 1728" Wipe Samples NIOSH 7500 (XRD)

MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD. BMiBl

Areas of known activity Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA Indoor Air (living rooms, family Asbestos NIOSH 7400 wkgroup detection limits method. rooms)

NYC-WTC_000408653

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408653Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →