NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 68 pages

WTC environmental plan, EPA review, 2005

Machine-extracted title · confidence 46%

EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.

NYC-WTC_000437748–000437815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

stub of about 100-200 pg, which is a moderately heavy loading. Adjust the number of aliquots as needed to obtain the target loading.

Prepare a 10-fold dilution of the above suspension to get a suspension of 1-2 mg dust per mE of isopropanol. Sonicate the suspension in an ultrasonic bath for one minutes. Remove the suspension and gently shake it to suspend all particles. Wait one minute to allow the coarse particles to settle. Collect a 10-pE aliquot of the suspended mixture using an Eppendorf pipette with the modified tip and transfer to a prepared polycarbonate/adhesive tab substrate. This will yield a loading on a 12-mm SEM stub of about 10-20 pg, which is a light loading. Adjust the number of aliquots as needed to obtain the target loading.

Alternatively, prepare a lightly loaded sample using the filtration method as follows: Use a Millipore filter apparatus for use with 25-mm filters for filtration. Place a few drops of isopropanol on the fritted glass surface and place the 25-mm polycarbonate filter (0.4-um pore size) on the isopropanol. Attach the top of the apparatus and add a few milliliters of isopropanol to the filter so that no part of it is exposed to air. Sonicate the suspension (diluted as described in previous paragraph) in an ultrasonic bath for one minute. Remove the suspension and gently shake it to suspend all particles. Wait one minute to allow the coarse particles to settle. Collect 1 mL of the suspended mixture using a pipette and filter it through the polycarbonate filter. Actual amounts for filtration will vary based on sample loading. The goal is to have a loading on a 12-mm SEM stub of about 10-20 pg, or about 5-10 percent area coverage, which is a light loading. Adjust the volume of the aliquot to filter as needed to obtain the target loading.

Place the filter on a carbon adhesive tab on a standard SEM aluminum mount. The filter needs to be completely flat on the SEM stub. This can be achieved by forming the wet filter into a gentle U-shape using forceps and the side of the forefinger, then placing the bottom curve of the filter onto the center of the carbon adhesive tab and slowly releasing the sides so they lay flat. Trim the edges of the filter using a razor blade.

After drying, coat the samples on the polycarbonate or polycarbonate/adhesive tab substrates with carbon using a carbon evaporator with a rotating stage. Transfer the stubs to the SEM in a clean, covered container.

12.0 Analysis

12.1 Analysis by Polarized Light Microscopy

Polarized light microscopy will be conducted using the general techniques outlined in EPA 600/R93/116 (4). For this procedure, four slides (prepared as described in section 11.4) will be analyzed. The fraction of fibers with refractive index greater than 1.55 (or 1.605) will contain mineral wool, which includes both slag wool and rock wool, and possibly some E-type glass and ceramic fibers. The

42

CITY_21MC100_003219531

NYC-WTC_000437789

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437789Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →