5. Shut off furnace. 6. Allow sample to cool before removing from furnace. 7. Weigh the ashed sample to the nearest 0.0005 g and record the result.

11.3 Sieving

Sieve the sample through a 150-pm sieve using a Retsch ultrasonic sieve shaker, or similar. Three-inch diameter sieves are recommended to minimize sample loss from particles being trapped in the sieve. The ultrasonic shaker will be operated at 20-minutc intervals at the following settings: 20, 40, 60, 70, 80, then back down to 50 and 20. This will provide amplitudes ranging from 0 to 1.5 mm.

Transfer the large and small fractions to clean pieces of weighing paper and weigh to the nearest 0.0005 g. Archive the fraction greater than 150-Lim.

11.4 Preparation of Sample for Polarized Light Microscopy

Split the less than 150-urn sample fraction using the cone and quarter method. Collect one comer for analysis and archive the other three quarters. Weigh the quarter split to the nearest 0.0005 g and place it into a glass vial. Make a suspension of 10-20 mg dust per mL of isopropanol. The amount of isopropanol needed will vary depending on the amount of dust; the target dilution is 10-20 mg per mL.

Cut an Eppendorf pipette tip with a razor blade to increase the opening to approximately 1 mm.

Place the suspension in an ultrasonic bath for one minute, then remove the suspension from the ultrasonic bath and shake it gently to suspend all particles. Collect a lO-pL aliquot of the mixture using an Eppendorf pipette with the modified tip and transfer to a glass slide. Prepare 4 such slides. Allow them to dry, then add a drop of 1.55 (or 1.605) refractive index oil.

11.5 Preparation of Sample for SEM Analysis

Prepare the SEM substrate on aluminum stubs using 0.4-pm pore size polycarbonate filters, carbon adhesive tabs. Using an 11 mm filter punch and placing the filter between two filter separators, punch a circle the size of the carbon tab into the filter. Place carbon adhesive tab affixed to an aluminum stub on the dull side of the 11 -mm polycarbonate filter such that the shiny side of the filter exposed. If available, a 13-mm diameter polycarbonate filter may be used in place of the punched out 11-mm filter.

Collect a lO-pL aliquot of the mixture from the PLM sample preparation using the Eppendorf pipette with the modified tip and transfer to a prepared polycarbonate/adhesive tab substrate. This will yield a loading on a 12-mm SEM

41

CITY_21MC100_0 03219530

NYC-WTC_000437788

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437788Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →