the analysis should be performed with a beam size of 10-20 pm or equivalent area raster. All calibration spectra will be saved with the corresponding data set. The calibration data will be used for inter- as well as intra-laboratory comparisons. This calibration is in addition to, and not a substitute for the normal EDS calibration recommended by the EDS manufacturer which will be performed at regular intervals as specified by the EDS manufacturer.

Backscattered electron detector calibration can be performed on the same BIRl-G material by adjusting the detector brightness and contrast to achieve the following conditions. The epoxy on the BlRl-G reference material will be at 0 in a 256 grayscale image and the brass mounting tube will be at 256. The BIRl-G basalt glass should fall at approximately 130-140 gray scale units

11.0 Procedure

11.1 Weighing and Splitting

Weighing and splitting should be performed under a negative flow HEPA hood. If the fan speed is set too high, loss of particles may occur. The fan speed may need to be adjusted to prevent the loss of fine particles.

Obtain an analytical balance with an accuracy of 0.0005 g and preweigh a clean piece of weighing paper. Transfer the dust from the sample vial to the weighing paper and determine the weight of the dust. Split the sample with a clean razor blade using the cone-and-quarter method. If there are large clumps of organic fibers, such as hair or lint, temporarily remove the hair with a pair of forceps and tap the forceps lightly with another tool over a piece of weighing paper to remove fine particles. Center the fine fraction on the paper and split the sample into four equal parts using a razor blade. Collect opposite comers of the sample) for analysis and archive the other half. Quarter the larger organic fiber bundles the same way, keeping half to proceed to the ashing step and half for archival purposes.

Place the two quarters for ashing into a pre-weighed crucible. Weigh the split and record the results.

11.2 Ashing

Place the ceramic crucibles containing the samples into a furnace.

The furnace program should proceed as follows: 1. Increase temperature by 1 °C/minute until sample reaches 250 °C. 2. Hold temperature at 250 °C for 4 hours. 3. Increase temperature by 1 °C/minute until sample reaches 480 °C. 4. Hold temperature at 480 °C (sufficient for decomposing organics) for 8 hours. Do not exceed 500 °C.

40

CITY_21MC100_0 03219529

NYC-WTC_000437787

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437787Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →