f. Use sample collection filters which are either polycarbonate having a pore size of less than or equal to 0.4 mum or mixed cellulose ester having a pore size of less than or equal to 0.45 mum.

g. Place these filters in series with a pore size of 5.0 mum (to serve as a diffuser) and a support pad. See the following Figure 1:

* Display Image

h. When polycarbonate filters are used, position the highly reflective face such that the incoming particulate is received on this surface.

i. Seal the cassettes to prevent leakage around the filter edges or between cassette part joints. A mechanical press may be useful to achieve a reproducible leak-free seal. Shrink fit gel-bands may be used for this purpose and are available from filter manufacturers and their authorized distributors.

j. Use wrinkle-free loaded cassettes in the sampling operation.

5. Pump setup.

a. Calibrate the sampling pump over the range of flow rates and loads anticipated for the monitoring period with this flow measuring device in series. Perform this calibration using guidance from EPA Method 2A each time the unit is sent to the field (See Reference 6 of Unit III.L.).

b. Configure the sampling system to preclude pump vibrations from being transmitted to the cassette by using a sampling stand separate from the pump station and making connections with flexible tubing.

c. Maintain continuous smooth flow conditions by damping out any pump action fluctuations necessary.

d. Check the sampling system for leaks with the end cap still in place and the pump before initiating sample collection. Trace and stop the source of any flow indicated by the flowmeter under these conditions.

e. Select an appropriate flow rate equal to or greater than 1 L/min or less than 10 L/min for 25 mm cassettes. Larger filters may be operated at proportionally higher flow rates.

f. Orient the cassette downward at approximately 45 degrees from the horizontal.

g. Maintain a log of all pertinent sampling information, such as pump identification number, calibration data, sample location, date, sample identification number, flow rates at the beginning, middle, and end, start and stop times, and other useful information or comments. Use of a sampling log form is recommended. See the following Figure 2:

♦ Display Image

h. Initiate a chain of custody procedure at the start of each sampling, if this is requested by the client.

http://lexis/research/retrieve?_m=el35t2ca3d266867e53ci261df3205722&_fnitstr=FULL6 ... 02/04/2002 CITY_21MC100_012558679

NYC-WTC_000219939

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000219939Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

WTC health criteria appendix, Dec 2001 · page 6

NYC-WTC_000176140

Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.

Similarity score 0.920 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →