NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 29 pages

Ambient air sampling report, Rector Street site

Machine-extracted title · confidence 28%

ATC ambient air sampling at 40 Rector Street; contents include procedures and results.

NYC-WTC_000437420–000437448
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

40 Rector Holdings, LLC ATC Project No.: 19855-0001 C/0 Tannenbaum Helpern Syracuse & Hirschtritt LLP October 25,2001 Ambient Air Sampling - 40 Rector Street Page 2 Of 7

Based upon analytical sample results following both cleaning episodes recording levels within the AHERA clearance requirement, it is ATC’s opinion that the ambient air samples collected and lAQ measurements collected throughout the building are representative of the ambient conditions at the time of testing and that the areas tested meet an acceptable criterion for re-occupancy^

Ambient Air Sampling - Initial Cleaning Between September 20 and 28, 2001, ATC collected a minimum of five ambient air samples per floor representative of ambient air conditions following the initial cleaning of 40 Rector Street. All field generated air monitoring data and chain of custody forms and laboratory generated analytical data is included in Attachment 2 at the end of this report. A summary of the data is provided in Table 1. Table 1 Summary of Ambient Air Sample Results Initial Cleaning Floor Analytical Result Floor Analytical Result 1 No structures detected______ 10 All samples <70 s/mm^ 2 All samples <70 s/mm^______ 11 All samples <70 s/mm^ 3 All samples <70 s/mm^ 12 All samples <70 s/mm^ 4 All samples <70 s/mm^ 14 All samples <70 s/mm^ 5 Sample set average 23 s/mm^ 15 ' All samples <70 s/mm^ 6 All samples <70 s/mm^______ 16 No structures detected 7 All samples <70 s/mm^ 17 All samples <70 s/mm^ 8 All samples <70 s/mm^______ 18 All samples <70 s/mm^ 9 All samples <70 s/mm^ 19 All samples <70 s/mm^

Based upon the analytical results recording levels within the AHERA clearance requirement, it is ATC's opinion that the ambient air samples collected throughout the building are representative of the ambient conditions at the time of testing and that the areas tested meet an acceptable criterion for re-occupancy.

Ambient Air Sampling - Subsequent Cleaning Between October 22 and 23, 2001, ATC collected a minimum of five ambient air samples per floor representative of ambient air conditions following the subsequent cleaning of 40 Rector Street. All field generated air monitoring data and chain of

ATC Associates Inc. © 2001

CITy_21MC100_007087976

NYC-WTC_000437422

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437422Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117493 · Box DEP Box 46

Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.

Similar indexed content