Ambient air sampling report, Rector Street site

Machine-extracted title · confidence 28%

ATC ambient air sampling at 40 Rector Street; contents include procedures and results.

NYC-WTC_000437420–000437448
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I I 40 Rector Holdings, LLC C/0 Tannenbaum Helpern Syracuse & Hirschtritt LLP ATC Project No.; 19855-0001 October 25, 2001 Ambient Air Sampling - 40 Rector Street Page 4 Of 7 I ■ TABLE 3 -TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED I PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION I Carbon Dioxide (CO,) <700 parts per million (ppm) ASHRAE 62

above background level I Carbon Monoxide (CO) 9 ppm USEPA NPAAQS (as cited in ASHRAE 62) 50 micrograms per cubic USEPA NPAAQS (as cited I Respirable Particles (PMk,) Temperature meter of air (gg/m^) Summer: 73-79°F at 50% in ASHRAE 62) ASHRAE55

I RH Winter; 68-75°F at 50% RH______ ___________ I Relative Humidity Total Volatile 30 - 60 % ASHRAE 55

Organic 1 ppm AIHA I Compounds (TVOC) USEPA = United States Environmental Protection Agency

I NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association

I REAL-TIME MONITORING ATC collected readings of the six listed parameters within representative areas inside the building and one set of readings outside of and adjacent to the building. The indoor I air quality field reports are included in Attachment 1 at the end of this report. These areas were unoccupied at the time of this assessment.

I All parameters measured during the lAQ assessment were within recommended guideline ranges, however, an odor of smoke was detected in several locations. This odor infiltrated the building from fires at the nearby World Trade Center site. This odor I does not constitute a health hazard although building occupants may consider the odor unpleasant and annoying. Sensitive individuals, such as asthmatics, may find the odor irritating. As a potential remedy to the odor, ATC provided a recommendation on I October 2. 2001 for building operation modifications to minimize the odor entrainment into the building. The recommendation suggested that the-building consider installing charcoal-impregnated filters on the HVAC system intakes to reduce odor entrainment; I ATC Associates Inc. © 2001

CITY__21MC100_00 708 7 9 78

NYC-WTC_000437424

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437424Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117493 · Box DEP Box 46

Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.

Similar indexed content

Compare copies and versions →