BENCH
srettuMNC
NOHMAL COLUMN
CHAfKE
HEAVY SOTTO* CHAKCE
Fig. 5-14. Charge distribution in
bench blasting. (See Table 5-1
for typical charge weights)
to the underlying rock is of no concern, and where no natural surface
is available for horizontal control.^® Depth below intended bottom may
be 0.2 to 0.3 times burden to assure that the desired depth is reached.
Inclined blastholes require less subdrilling to pull all the rock to
bottom than do vertical holes (a(2) above). Because of the commonness
of stress concentrations and consequent stability problems near the toe
of the slope, overshooting there should be avoided.
(7) SecondarA£_Blasting_. Bench blasting ideally reduces all rock
to a desired rubble size range. Thia is basic in order to facilitate
handling of rubble, to meet limitations imposed by equipment, e.g.,
bucket size, or to produce a usable material. Actually, even a satis
factory blast may leave a few oversize blocks that must be broken by
secondary blasting (pop blasting) or other means. Large blocks may
be broken by blasting with light charges placed in small drill holes in
the block. A quick method for smaller blocks, known as mudcapping,
involves blasting with a part of a stick of powder placed against the
block and covered with mud or a bag of sand. Light shaped charges are
effective in block breakage also. Mudcapping and shaped charges may
produce objectionable airblast, and breakage with a drop ball is pre
ferred wherever that equipment is adequate and available.
b. Coyote Blasting. Trenching, and Cratering.
(1) Coyote blasting (gopher hole or tunnel blasting) is the prac
tice of firing large charges of explosives placed in tunnels driven into
a rock face at floor level. It is used where large quantities of material
are to be removed cheaply. Coyote blasting works best in faces 75 to
175 ft high when using one level of tunnels. Higher banks can be blasted
if the tunnels are supplemented with large blastholes to about one-third
the depth of the face.
5-12
CITY_21MC100_0 12669683
NYC-WTC_000435913
OCR can misread numbers and units. Confirm readings against the page image before using them.