are Bureau of Mines observed airblast pressures for rpultiple-hole
quarry blasts. For the quarry blast data, the charge weight is the
maximum charge'detonated per delay interval. The charge per delay
interval is the sum of the charges in the holes that are detonated simul
taneously. From the location of the data points, the scaled depth of
burial for the quarry blast is usually less than 1.0. This scaled depth
of burial corresponds roughly to the scaled burden for each shot hole.
From Fig. 7-1, a scaled distance of 20 ft/lb^/3 should be sufficient to
assure airblast pressures of less than 0.1 psi for multiple-hole quarry
blasts that are well stemmed and cap initiated.
c. Excessive Airblast Pressure.
(1) The primary causes of excessive airblast pressures are in
sufficient burden, insufficient stemming in each blasthole, exposed deto
nating fuse, and adverse weather conditions. A well-designed blasting
round that breaks and moves rock efficiently seldom produces exces
sive airblast pressures. If detonating fuse is used, it should be
covered with sand to minimize airblasts. Exposed detonating fuse and
lack of stemming in blastholes can increase airblast pressures by a
factor of 10 or more.
(2) Under certain adverse weather conditions, such as tempera
ture inversions, cloud cover, and high wind velocity, local high airblast- ,
pressure regions can develop at large distances from the shot
point,33, 34
(3) These local high-pressure regions are a result of focusing of
sound waves. As temperature inversions exist most frequently during
the period from 1 hr before sunset to 2 hr after sunrise, blasting opera
tions should be confined to the intervening daytime period if airblast
is to be avoided. Postponement of blasting operations should be con
sidered during daytime hours when a heavy low-level cloud cover exists.
Also blasting operations should not be conducted when wind velocities
in excess of 15 mph are in the direction of nearby residential structures.
d. Recording Equipment.
(1) Airblast pressures are recorded generally by two types of
equipment--microphones and piezoelectric pressure gages. The micro
phone has proven satisfactory for pressure measurements from 0.1 to
1 psi. Overpressures greater than 1 psi are usually recorded by the
piezoelectric type of gage.
(2) Air waves from multiple-hole delayed blasting produce record
ing problems not encountered with instantaneous surface blasts. A
7-4