NYC 9/11 Public Portal Document
Section 2 - Ambient Air Monitoring Program Revision No.: 0
130 Liberty Street Deconstruction Plan Date: September 7, 2005
Lower Manhattan Development Corporation
8.1.1 Target Air (luality Levels
Any 24-hour PMio and PM2.5 value in excess of the Target Air Quality Level will be considered
an “exceedance” and the actions described below will be taken.
During the first week of sampling, any sample of an analyte, other than PMio and PM2.5, in
excess of 3 times the Target Air Quality level for that analyte unless superseded by a USEPA
Site Specific Trigger Level, will be considered an exceedance and the actions described below
will be taken.
Following the first week of sampling, a cumulative average will be established based initially on
the first week’s results, to which will be added daily values as results are received from the
laboratory. A cumulative average value for any analyte other than PM2,5 and PMio in excess of
the relevant Target Air Quality Level will be considered an exceedance and the actions described
below will be taken.
Exceedances of an established Target Air Quality Level for any analyte calculated as provided
above will result in an evaluation of engineering controls and work techniques in the source area.
The evaluation of engineering controls and work techniques shall determine whether: (i)
negative pressure is being maintained in active work areas at the required levels (ii) there are
breaches in the containment in active work areas, and (iii) there are any visible emissions from
the containment areas. In addition, the evaluation will consider other potential sources
contributing to or causing the exceedance.
8.1.2 USEPA Site Specific Trigger Levels
Any 24-hour value (eight-hour value in the case of asbestos and silica) in excess of the USEPA
Site Specific Trigger Level will be considered an “exceedance” and the actions described below
will be taken.
Exceedance of USEPA Site Specific Trigger Levels will result in a stoppage of work associated
with the exceedance until an evaluation of emission controls is performed and corrective action
is in place. The USEPA Site Specific Trigger Levels are applicable to individual sample results.
If any of the individual sample results exceed an USEPA Site Specific Trigger Level, then
notification must be made to the USEPA Region 2, NYCDEP and NYSDOL as well as LMDC
and LMCCC. Work will be reinitiated once the USEPA Region 2 has agreed (and NYSDOL
during the Abatement Phase in the case of asbestos exceedances) to the corrective action(s)
proposed to prevent the potential for exceedances in future work and such corrective actions
have been implemented. The only exception to the work stoppage requirement will be for an
exceedance of the USEPA Site Specific Trigger Level for PM2.5 at one of the off-site roof top
locations. If the USEPA Site Specific Trigger Level for PM2.5 is exceeded at an off-site roof top
location, regulator notifications as described above will be made and an assessment, with the
active involvement of the USEPA, will be performed to determine if the exceedance was due to
an off-site or regional condition unrelated to 130 Liberty Street work If the assessment
8-2
CITY_DEP_WORBY_CANNATA_SUBP_000075898
NYC-WTC_000424731
OCR can misread numbers and units. Confirm readings against the page image before using them.