Sample Collection
Asbestos and Fibrous Glass
ATC collected asbestos and fibrous glass samples of air on 25 millimeter, mixed-
cellulose ester filter membranes (0.45 & 0.8 micron pores respectively) contained in
manufacturer pre-assembled, three-piece cassettes with electrically conductive, extended
cowls. Pump flow rates were determined (both at the start and at the end of the sampling
period and periodically by a representative of the NYCDEP) with a secondary standard
(rotameter) that is calibrated quarterly against a primary standard (Gilian Instrument
Corporation primary flow calibrator “Gilibrator”). Fibers from ambient air were
collected with the filter cassette open-faced and positioned between three to five feet
above the floor.
Silica
In order to collect the desired Silica air samples for analysis, ATC performed the
following tasks for air collection. A desired filter and support pad was placed into a three-
piece cassette and inserted into the cyclone, which pressed firmly into the center ring of
the cassette.
ATC calibrated the pump with the cyclone-cassette assembly in-line using a primary
standard calibrator. The pumps, complete with cyclone-cassette assembly, were set in the
breathing zone. The pump remained in their set positions for the entire sampling period.
At the end of the sampling period, the cyclone/cassette assembly was removed from the
holder. The cyclone was then removed from the cassette and transported to the lab for
analysis.
Air Sample Analysis
Fibrous Glass
PCM fibrous glass clearance samples were analyzed by ATC’s New York City laboratory
utilizing the PCM method of analysis. The microscope used for sample analysis was
equipped with a phase contrast condenser. Sizing and fiber counts were performed at
400X magnification. Samples were analyzed by the National Institute of Occupation
Safety and Health (NIOSH) Method 7400 using method “A” counting rules. Method “A”
rules count only those fibers that have a length greater than five microns and a length-to-
width ratio greater than three-to-one. All air sample results are reported in fibers per
cubic centimeter of air (f/cc).