WTC Tremolite fiber monitoring, 2000

Machine-extracted title · confidence 41%

Coordination and monitoring for asbestos-related Tremolite fiber sampling.

NYC-WTC_000435232–000435267
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EPA R8 Multimedia Asbestos Sampling: Libby,MT January 4, 2000

mesothelioma (cancer effects). Limited data suggest that chronic exposures to chrysotile fiber levels of 5-20 f/mL can cause asbestotic changes (ATSDR 1999), but data are not sufficient to derive a reliable chronic MRL or RfC for asbestosis. However, methods have been established for estimating the excess risk of lung cancer and/or mesothelioma, and it is considered likely that exposure levels that protect against unacceptable risk of lung cancer/mesothelioma (in the range of 0.1 to 0.0001 f/mL; see below) will also protect against unacceptable risk of asbestosis.

The basic equation used to estimate cancer risk is:

Risk = Concentration (f/mL) * Unit Risk (risk per f/mL)

Thus, the data needs are an estimate of airborne asbestos concentration and an estimate of cancer risk per unit concentration.

Measurement of Asbestos Concentration in Air

There are a number of techniques for measuring asbestos fibers in air, all of which are based on visual identification of structures as asbestos fibers. Most historical human health data and many regulatory limits for asbestos exposure in air are based upon asbestos fiber concentrations measured using phase contrast microscopy (PCM) (see Table 2). In this method, fiber material is defined as having a length >5 microns and an aspect ratio (length to diameter ratio) of three or more. Results are generally reported as fibers per milliliter of air (f/mL).

More recently, a number of other methods have been developed for quantitative or qualitative measurement of asbestos fibers in air, including transmission electron microscopy (TEM), and x-ray diffraction (XRD). These methods are generally more sensitive than PCM, and also allow visualization and quantification of asbestos fibers that are thinner than those visible under PCM. This is important because it is likely that the toxicity of long thin fibers is greater than that of shorter thicker fibers (Berman et al., 1995). Based on this, asbestos fibers in air wili be quantified by TEM. Detailed rules for identifying asbestos fibers of biological concern by TEM are provided in ISO method 10312. This method is an international standard procedure that is recommended for quantifying asbestos fibers that are believed to be the chief source of human health concern (Berman and Crump 1999).

Unit Flisk for Asbestos in Air

It is mandatory that the unit risk value used to calculate cancer risk be based on the same type of asbestos measurement technique as used to quantify asbestos concentration in air. That is, it is not correct to estimate risk by multiplying a concentration based on TEM fibers per mL by a unit risk based on PCM fibers per mL. Thus, risk-based values shown in Table 2 cannot be used

J

CITY_21MC100_009479258

NYC-WTC_000435241

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000435241Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →