NYC 9/11 Public Portal Document
IRIS Summary — Asbestos Page 6 of 11
(iviesotneiioma:
Insulation Mixed 375 1.5E-6 Selikoff et al.,
workers 1979; Peto et
al., 1982
Insulation Amosite 400 l.OE-6 Seidman et
Products al., 1979
Textile Chrysotile 67 3.2E-6 Peto, 1980;
Products Peto et al.,
Manufacturer 1982
Cement Mixed 108 1.2E-5 Finkelstein,
Products 1983
_ II.C.3. Additional Comments (Carcinogenicity, Inhalation Exposure)
Risks have been calculated for males and females according to smoking habits for a
variety of exposure scenarios (U.S. EPA, 1986). The unit risk value is calculated for
the additive combined risk of lung cancer and mesothelioma, and is calculated as a
composite value for males and females. The epidemiological data show that cigarette
smoking and asbestos exposure interact synergistically for production of lung cancer
and do not interact with regard to mesothelioma. The unit risk value is based on risks
calculated using U.S. general population cancer rates and mortality patterns without
consideration of smoking habits. The risks associated with occupational exposure were
adjusted to continuous exposure by applying a factor of 140 cu.m/50 cu.m based on the
assumption of 20 cu.m/day for total ventilation and 10 cu.m/8-hour workday in the
occupational setting.
The unit risk is based on fiber counts made by phase contrast microscopy (PCM) and
should not be applied directly to measurements made by other analytical techniques.
The unit risk uses PCM fibers because the measurements made in the occupational
environment use this method. Many environmental monitoring measurements are
reported in terms of fiber counts or mass as determined by transmission electron
microscopy (TEM). PCM detects only fibers longer than 5 um and >0.4 um in
diameter, while TEM can detect much smaller fibers. TEM mass units are derived from
TEM fiber counts. The correlation between PCM fiber counts and TEM mass
measurements is very poor. Six data sets which include both measurements show a
conversion between TEM mass and PCM fiber count that range from 5-150 (ug/cu.m)/
(f/mL). The geometric mean of these results, 30 (ug/cu.m)/(f/mL), was adopted as a
conversion factor (U.S. EPA, 1986), but it should be realized that this value is highly
uncertain. Likewise, the correlation between PCM fiber counts and TEM fiber counts
is very uncertain and no generally applicable conversion factor exists for these two
measurements.
In some cases TEM results are reported as numbers of fibers <5 um long and of fibers
longer than 5 um. Comparison of PCM fiber counts and TEM counts of fibers >5 um
show that the fraction of fibers detected by TEM that are also >0.4 um in diameter (and
detectable by PCM) varies from 22-53% (U.S. EPA, 1986).
It should be understood that while TEM can be specific for asbestos, PCM is a
nonspecific technique and will measure any fibrous material. Measurements by PCM
which are made in conditions where other types of fibers may be present may not be
reliable.
In addition to the studies cited above, there were three studies of asbestos workers in
mining and milling which showed an increase in lung cancer (McDonald et al., 1980,
Nicholson et al., 1979; Rubino et al., 1979). The slope factor calculated from these
studies was lower than the other studies, possibly because of a substantially different
fiber size distribution, and they were not included in the calculation. The slope factor
was calculated by life table methods for lung cancer using a relative risk model, and for
http;//www.epa.gov/iris/subst/037 1 .htm 1/2/2002
CITY_21MC100_011101454
NYC-WTC_000338421
OCR can misread numbers and units. Confirm readings against the page image before using them.