NYC 9/11 Public Portal Document
Amosite) J_________ Asbestos 374 0.49 Henderson and Products Enterline, 1979 Cement 89 0.53 “WdU^., 1979 Products 112 6.7 Finkelstein, 1983 Mesothelioma: Insulation Mixed 375 1.5E-6 Selikoff et al., (workers 1979; Peto et al., 1982__________ Insulation Amosite 400 l.OE-6 Seidman et al., Products 1979 _________ Textile Chrysotile 67 3.2E-6 Peto, i980; Peto et Products al., 1982 Manufacturer Cement Mixed 108 1.2E-5 Finkelstein, 1983 Products i
_ II.C.3. Additional Comments (Carcinogenicity, Inhalation Exposure)
Risks have been calculated for males and females according to smoking habits for a variety of exposure scenarios (U.S. EPA, 1986). The unit risk value is calculated for the additive combined risk of lung cancer and mesothelioma, and is calculated as a composite value for males and females. The epidemiological data show that cigarette smoking and asbestos exposure interact synergistically for production of lung cancer and do not interact with regard to mesothelioma. The unit risk value is based on risks calculated using U.S. general population cancer rates and mortality patterns without consideration of smoking habits. The risks associated with occupational exposure were adjusted to continuous exposure by applying a factor of 140 cu.m/50 cu.m based on the assumption of 20 cu.m/day for total ventilation and 10 cu.m/8-hour workday in the occupational setting.
The unit risk is based on fiber counts made by phase contrast microscopy (PCM) and should not be applied directly to measurements made by other analytical techniques. The unit risk uses PCM fibers because the measurements made in the occupational environment use this method. Many environmental monitoring measurements are reported in terms of fiber counts or mass as determined by transmission electron microscopy (TEM). PCM detects only fibers longer than 5 um and >0.4 um in diameter, while TEM can detect much smaller fibers. TEM mass units are derived from TEM fiber counts. The correlation between PCM fiber counts and TEM mass measurements is very poor. Six data sets which include both measurements show a conversion between TEM mass and PCM fiber count that range from 5-150 (ug/cu.m)/(f/mL). The geometric mean of these results, 30 (ug/cu.m)/(f/mL), was adopted as a conversion factor (U.S. EPA, 1986), but it should be realized that this value is highly uncertain. Likewise, the correlation between PCM fiber counts and TEM fiber counts is very uncertain and no generally applicable conversion factor exists for these two measurements.
In some cases TEM results are reported as numbers of fibers <5 um long and of fibers longer than 5 um. Comparison of PCM fiber counts and TEM counts of fibers >5 um show that the fraction of fibers detected by TEM that are also >0.4 um in diameter (and detectable by PCM) varies from 22-53% (U.S. EPA, 1986).
It should be understood that while TEM can be specific for asbestos, PCM is a nonspecific technique and will measure any fibrous material. Measurements by PCM which are made in conditions where other types of fibers may be present may not be reliable.
In addition to the studies cited above, there were three studies of asbestos workers in mining and milling which showed an increase in lung cancer (McDonald et al., 1980, Nicholson et al., 1979; Rubino et al..
CITY_21MC100_009039514
NYC-WTC_000302731
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
4 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
4 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338416
Draft IRIS summary page for Asbestos (CASRN 1332-21-4) with exposure information.
5 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
4 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301400
HSDB compilation entry on asbestos manufacturing, use, and properties.
4 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337538
Academic article on TEM detection limits for asbestos fibers and regulatory context.
4 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437306
Lab report discussing TEM vs optical microscopy and regulatory asbestos limits.
4 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289570
Glossary and reference material on asbestos terms and regulations used for lab context.
4 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195068
Medical reference document providing an overview of asbestos substances, clinical effects, and treatment protocols for health surveillance purposes.
4 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151635
EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.
2 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140259
Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
2 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
2 shared non-person entities · 1 shared topics · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000338416
Draft IRIS summary page for Asbestos (CASRN 1332-21-4) with exposure information.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276455
EPA/NCEA draft on exposure and [name] evaluation relating to World Trade Center.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148952
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435232
Coordination and monitoring for asbestos-related Tremolite fiber sampling.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320382
Background on air sampling methods (PCM and TEM) used for asbestos assessment near WTC.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250307
Preliminary health report authors and affiliations for WTC response.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000338416
Draft IRIS summary page for Asbestos (CASRN 1332-21-4) with exposure information.
Similar indexed content
NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
Similar indexed content
NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
Similar indexed content
NYC-WTC_000301400
HSDB compilation entry on asbestos manufacturing, use, and properties.
Similar indexed content
NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
Similar indexed content