NYC 9/11 Public Portal Document

FROM: George - Taylor Env.

TO: kmckinneghealth.nyc.gov

COPIED: LEMPERT, ALEX

DATE: 10/02/2002 12:15:49 PM

SUBJECT: Stuy HS Summary of work.

10.2.02

Kelly R McKinney PE Associate Commissioner, Environmental Health NYC Department of Health and Mental Hygiene 125 Worth Street,Room 616 New York,NY 10013

Re: Stuyvesant High School 345 Chambers Street New York, NY.

Dear Mr.McKinney

As requested please find enclosed summary of all work performed at the aforementioned facility. (7.13.02-8.31.02)

Cleaning and Testing of Unit Ventilators

Kiss Construction Inc.(KCI) performed environmental cleaning of all wall and ceiling mounted Unit Ventilators within the facility. This cleaning work was performed within tent enclosures under negative pressure. Each Unit Ventilator was visually inspected by Taylor Environmental Group,Inc.(TEG) and if found to be free of visible dust/debris a wipe sample was collected from the Unit Ventilator to be tested for lead. If sample results indicated a lead concentration exceeding the NYC Board of Education/NYC School Construction Authority ("NYC SCA") clearance level of 20 ug/sq.ft.then the Unit Ventilator was re-cleaned and re-tested.

Air Monitoring-

During the cleaning of the Unit Ventilators within each tent enclosure, TEG performed personal (OSHA) air monitoring on KCI's personnel working within each tent, in addition to ambient area monitoring outside each tent. Personal and area samples were analyzed for lead via NIOSH Method 7082, and the results of all samples collected indicated airborne lead concentrations below the current OSHA action level of 30 ug/m3.

2. HVAC System Wipe Sample Testing

CITY_21MC100_013074366

NYC-WTC_000434664

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000434664Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000429996

Summary memo detailing project team and partner firms for Stuyvesant High School work, Aug 2002.

Similar indexed content

Compare copies and versions →