Rc: Summary of Work Performed Stuyvesant High School 345 Chambers Street, New York, NY NYC SCA Project #: M477-152i7, LLW#: 29881

The following represents the summary of work performed at the aforementioned facility through August 26, 2002;

The SCA retained Taylor Environmental Group, Inc. (TEG) whom performs environmental consulting and analytical services under a requirements service contract. TEG is licensed by the NYS Department of Labor and the US EPA to perform asbestos and lead based paint related environmental consulting services and is a pre-qualified NYC SCA Consultant.

Kiss Construction Inc. (Kiss) performs asbestos and lead based paint remediation services was also retained under their current requirements service contract. Kis.'? is licensed by the NYS Department of Labor and the US EPA to perform a.sbestos and lead based paint abatement services.

Activities performed by TEG & Kiss are outlined as follows:

1. Cleaning and Testing of Unit Ventilators Kiss performed environmental cleaning of all wail and ceiling mounted Unit Ventilator.s within the facility. I'his cleaning work was performed within tent enclosures under negative pressure. Each Unit Ventilator was visually inspected by TEG and if found to be free of visible dust/debris a wipe sample was collected from the Unit Ventilator to be tested for lead. If sample results indicated a lead concentration exceeding the NYC Board of Education/NYC School Construction Authority (“NYC SCA”) clearance levels then the Unit Ventilator was recleaned and retested. Air Monitoring- During the cleaning of the Unit Ventilator.s within each tent enclosure, TEG performed personal (OSHA) air monitoring on Kiss’s personnel working within each tent, in addition to ambient area monitoring outside each tent. Personnel and area samples were analyzed for lead via NIOSH Method 7082.

2. HVAC System Wipe Sample Testing At the conclusion of all HVAC/Duct cleaning (performed by the HVAC Cleaning Contractor) on each floor, TEG collected wipe samples from the return and supply ducts within each zone to be analyzed for lead via EPA Method SW846-7420. In addition wipe samples to be analyzed for lead were collected from the air handling units for HVAC systems one (1) through fifteen (15) after they had been cleaned by the HVAC Cleaning Contractor.

3. General Cleaning At the conclusion of all Unit Ventilator and HVAC/Duct related cleaning work on each floor of the facility, Kiss performed general cleaning of the Unit Ventilators in each

CITY_21MC100_013380896

NYC-WTC_000245913

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000245913Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418887

Summary of environmental work at Stuyvesant High School; contractors and scope.

Similar indexed content

NYC-WTC_000418892

Summary of environmental work at Stuyvesant High School; contractors and scope.

Similar indexed content

NYC-WTC_000246075

Summary of environmental cleaning and testing at Stuyvesant High School.

Similar indexed content

Compare copies and versions →