NYC-WTC_000431341
TEM asbestos analysis with SAED/EDS on World Trade Center sample; date 09/17/01.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗TEM analysis with SAED/EDS for WTC sample 5516; 09/17/01.
NYC-WTC_000431355OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
I ATC Environmental, Inc.
I 104 East 25th Street New York, New York 10010
N.Y;C. School Construction Authority Approved N.Y. State ELAP #10879 I 30-30 Thomson Avenue Long Island City, NY 11101 ACCREDITED NVLAP Lab Code # 1187 Report Date; 09/17/01
I ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy {EDS) Method: AHERA Final Rule, EPA Federal Register {40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987 ^Sample IdenEifieation Analysis Paramecers
Project/Site: Worl^jrrade Cente£,NYj^ TEM Sample No.: 5516 - 59056
I ‘ Personal Exposure Monitoring Dace Received: 09/17/01 Grid Openings Analyzed: 10
I Project Sample No.: AHT 015 Average Grid Opening: 106.00 um
Air Volume:^1261iters Tocal Area Analyzed: 0.1124 mmZ
m Filter Type: MCE 25 mm diam., Pore Size: Q.45 um Analytical Sensitivity: 8.9 s/rnfn2 Effective Area: 385_mm2’ 0.0272 s/cc
I FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION '• Tocal Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >a5um Strucc/(nm2 Struct/cc nqm/ni3
I Chrysotile Asbestos 7 4 0 7 18 3 160.1 0.4893 16148
Amphibole Asbestos 0 0 0 0 0 0 0,0 0.0000 0 I Ambiguous 0 0 0 0 0 0- 0.0 0.0000 0
Total asbestos {includes ambiguous structures) 18 3 160.1 0.4893 16148
I Non-Asbescos No Identification d 0 0 0 0 0 0 0 0 0 0 0 0.0 0.0 0.0000 0.0000 N/A N/A
I Totals (Ail Structures) The escirnated uncertainty of this analysis is 1 standard deviacion. 18 3 160.1 0.4893 N/A
Non-asbestos fiber i.d. (EDS/SAED): None detected I Amphibole Asbestos Type; None detected
The Analysis'was carried out in accordance with the approved TEM method. I This laboratory is in compliance with the quality specified for the method.
I Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. I Director of Electron Microscopy
I CITY_21MC100_010237420
NYC-WTC_000431355
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000431341
TEM asbestos analysis with SAED/EDS on World Trade Center sample; date 09/17/01.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431339
TEM asbestos fiber analysis report for World Trade Center site, AHERA/SAED/EDS methods, dated 09/17/01.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232456
TEM asbestos fiber analysis report for the World Trade Center site dated September 17, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431344
TEM asbestos analysis with SAED/EDS for World Trade Center sample; date 09/17/01.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431343
TEM asbestos analysis (SAED/EDS) for World Trade Center sample, date 09/17/01.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431346
TEM asbestos analysis for World Trade Center sample; date 09/17/01.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431347
TEM asbestos analysis (SAED/EDS) for World Trade Center sample, date 09/17/01.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322885
TEM analysis with SAED/EDS identification for World Trade Center site, Sept 2001.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200048
Laboratory report documenting asbestos fiber analysis by TEM for air samples collected at the World Trade Center on September 17, 2001.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322889
Approved TEM results summary for School Construction project, World Trade Center site, Sept 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322891
TEM analysis of air sample for World Trade Center, Sept 2001.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322887
TEM analysis and volumes for air sample at World Trade Center, Sept 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000431341
TEM asbestos analysis with SAED/EDS on World Trade Center sample; date 09/17/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431339
TEM asbestos fiber analysis report for World Trade Center site, AHERA/SAED/EDS methods, dated 09/17/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232456
TEM asbestos fiber analysis report for the World Trade Center site dated September 17, 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322885
TEM analysis with SAED/EDS identification for World Trade Center site, Sept 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431344
TEM asbestos analysis with SAED/EDS for World Trade Center sample; date 09/17/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431343
TEM asbestos analysis (SAED/EDS) for World Trade Center sample, date 09/17/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000431341
TEM asbestos analysis with SAED/EDS on World Trade Center sample; date 09/17/01.
Similar indexed content
NYC-WTC_000431339
TEM asbestos fiber analysis report for World Trade Center site, AHERA/SAED/EDS methods, dated 09/17/01.
Similar indexed content
NYC-WTC_000232456
TEM asbestos fiber analysis report for the World Trade Center site dated September 17, 2001.
Similar indexed content
NYC-WTC_000322885
TEM analysis with SAED/EDS identification for World Trade Center site, Sept 2001.
Similar indexed content
NYC-WTC_000431344
TEM asbestos analysis with SAED/EDS for World Trade Center sample; date 09/17/01.
Similar indexed content