I ATC Environmental, Inc.

I 104 East 25th Street New York, New York 10010

N.Y.C. School Construction Authority Approved N.Y. State ELAP #10879 I 30-30 Thomson Avenue Long Island City, NY 11101 ACCREDITED NVLAP Lab Code # 1187 Report Date: 09/17/01 I ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TSM) ■ With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)

Method: AHERA Final Rule, ERA Federal Register (40 CFR, Part 7631, Vol. 52, No. 210,. October 30, 1987 I Sample Identification Analysis Parameters

TEM Sample No.: 5517 - 59057

I Project/Sice: world_Trade_Cencer,_Ny,_NX Personal Exposure Moniborinq Dace Received: 09/17/01 Grid Openings Analyzed: IQ

I Project Sample No.: NYE-009 Average Grid Opening: 106.0C um

Air Volume: 120 liters Total Area Analyzed: 0.1124 rnm2 H Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity Effective Area: 395 mm2 0.Q26S s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION

I Single Fibers Bundles Clusters Matrix Struct Total. Struct. Total Struct. >»5um ■Struct/mm2 Filter Struct/cc Air ngm/m3 H Chrysotile Asbestos 14 1 1 24 40 3 355.9 1.1418 37678

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

I Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

I Total asbestos (includes ambiguous structures) 40 8 355.9 1.1418 37678 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

I Totals (All Structures) The estimated uncertainty of this analysis is 1 standard deviation. 40 8 355. 9 1.1418 N/A

I Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is- in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

I Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

I CITY_21MC100_010237423

NYC-WTC_000232456

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000232456Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →